Invacare Pronto Air User Manual page 11

Personal transporter with mybody seating
Hide thumbs Also See for Pronto Air:
Table of Contents

Advertisement

DANGER!
Risk of death, serious injury, or damage
Corroded electrical components due to water, liquid
exposure, or incontinent users can result in death,
serious injury, or damage.
– Minimize exposure of electrical components to water
and/or liquids.
– Electrical components damaged by corrosion MUST
be replaced immediately.
– Wheelchairs that are used by incontinent users
and/or are frequently exposed to water/liquids may
require replacement of electrical components more
frequently.
1580058-B
DANGER!
Risk of death or serious injury
Failure to observe these warnings can cause an electrical
short resulting in death, serious injury, or damage to
the electrical system.
– The POSITIVE (+) RED battery cable MUST connect
to the POSITIVE (+) battery terminal(s)/post(s). The
NEGATIVE (-) BLACK battery cable MUST connect
to the NEGATIVE (-) battery terminal(s)/post(s).
– NEVER allow any of your tools and/or battery cable(s)
to contact BOTH battery post(s) at the same time.
An electrical short may occur and serious injury or
damage may occur.
– Install protective caps on positive and negative battery
terminals.
– Replace cable(s) immediately if cable(s) insulation
becomes damaged.
– DO NOT remove fuse or mounting hardware from
POSITIVE (+) red battery cable mounting screw.
DANGER!
Risk of death or serious injury
Electric shock can cause death or serious injury
– To avoid electric shock, inspect plug and cord for
cuts and/or frayed wires. Replace cut cords or frayed
wires immediately.
Safety
11

Advertisement

Table of Contents
loading

Table of Contents