Download Print this page

Trane 4YCY4036B-SF-1H Service Facts

Single packaged gas heating / electric cooling

Advertisement

Quick Links

Service Facts
SINGLE PACKAGED
GAS HEATING / ELECTRIC COOLING
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
WARNING:
PRODUCT SPECIFICATIONS
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]
Performance Heating
Input BTUH - 1st Stage (Natural Gas)
Input BTUH - 2nd Stage (Natural Gas)
AFUE
Temp. Rise — Min/Max (°F)
Orifice Qty / Drill Size (Natural Gas)
POWER CONN.—V/PH/HZ
Min. Brch. Cir. Ampacity
Fuse Size — Max. (amps)
Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz
R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT
Charge (lbs.)
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
© 2013 Trane
HAZARDOUS VOLTAGE- DISCONNECT POWER and DISCHARGE
4YCY4036B1075B
208-230/1/60
38000
1210
3.166
12.0 / 14.2
69
56250
75000
79.5
30 / 60
2 / #33
208-230/1/60
26.2
40
40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3320
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4
R410A
7.80
1/2
H X W X L
47.86 / 44.5 / 52.03
488 / 392
NOTICE: The manufacturer has a policy of continuous product and product data improvement, and it
4YCY4036B-SF-1H
4YCY4036B1075/1096B
CAPACITORS BEFORE SERVICING
4YCY4036B1096B
208-230/1/60
38000
1210
3.166
12.0 / 14.2
69
72000
96000
80.0
40 / 70
3 / #37
208-230/1/60
26.2
40
40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3320
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4
R410A
7.80
1/2
H X W X L
47.86 / 44.5 / 52.03
493 / 397
reserves the right to change design and specifications without notice.
1 Certified in accordance with the Unitary
Air-Conditioner Equipment certification
program, which is based on AHRI
Standard 210/240. Sound Power val-
ues are not adjusted for AHRI 270-95
tonal corrections.
2 All models are certified to UL 1995.
Ratings shown are for elevations up to
2000 ft. For higher elevations reduce
ratings at a rate of 4% per 1000 ft.
elevation.
3 Convertible to LPG.
4 This value is approximate. For more
precise value, see Unit Nameplate.
5 Based on U.S. Government Standard
Tests.
6 Filters must be installed in return air
stream. Square footages listed are
based on 300 f.p.m. face velocity. If
permanent filters are used size per
manufacturer's recommendation with
a clean resistance of 0.05" W.C.
7 Standard Air - Dry Coil - Outdoor.

Advertisement

loading

Summary of Contents for Trane 4YCY4036B-SF-1H

  • Page 1 WEIGHT Shipping (lbs.) / Net (lbs.) 488 / 392 493 / 397 NOTICE: The manufacturer has a policy of continuous product and product data improvement, and it reserves the right to change design and specifications without notice. © 2013 Trane...
  • Page 2 Service Facts CAUTION WARNING CONTAINS REFRIGERANT! SAFETY HAZARD! SYSTEM CONTAINS OIL AND REFRIGERANT UNDER This information is for use by individuals having adequate HIGH PRESSURE. RECOVER REFRIGERANT TO RE- backgrounds of electrical and mechanical experience. LIEVE PRESSURE BEFORE OPENING SYSTEM. Failure Any attempt to repair a central air conditioning product to follow proper procedures can result in personal illness may result in personal injury and/or property damage.
  • Page 3 Service Facts PRESSURE CURVES FOR 4YCY4036 Cooling with Thermal Expansion Valve INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71, 67, 63 AND 59 DEG F. OUTDOOR TEMPERATURE (Degree F) INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71, 67, 63 AND 59 DEG F. OUTDOOR TEMPERATURE (Degree F) COOLING PERFORMANCE CAN BE CHECKED WHEN THE OUTDOOR TEMP IS ABOVE 65 DEG F.
  • Page 4 Service Facts IMPORTANT: Retain this wiring diagram; please return this document to service information pack upon completion of work.
  • Page 5 Service Facts IMPORTANT: Retain this wiring diagram; please return this document to service information pack upon completion of work.
  • Page 6: Sequence Of Operation

    Service Facts Sequence of Operation (R) and (W1/W2) (jumped) contacts open signaling the control module to close the gas valve and de-energize the induced Operation of the unit heating or cooling cycles is controlled draft blower after approximately 5 second postpurge. The I.D. by the setting of the comfort control.
  • Page 7 Service Facts Indoor Fan Performance 4YCY4036B Horizontal Airflow 4YCY4036-HOR External Static Pressure (in. wg) Motor Speed Watts 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 Watts MED* 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 1144 Watts HIGH 1390 1376 1370 1366 1361 1354 1349 1351 1369...
  • Page 8 Service Facts CHARGING IN COOLING ABOVE 55°F OD R-410A Subcooling Charging Table AMBIENT 10 (ºF) Subcooling The preferred method is to weigh in the factory charge per the unit nameplate. If weighing in the charge is not Liquid Liquid practical, the following method can be used. The fol- lowing charging method is prescribed for systems with Temperature Pressure...
  • Page 9 Service Facts...
  • Page 10: Troubleshooting Chart

    Service Facts Troubleshooting Chart SYSTEM FAULTS REFRIGERANT CIRCUIT Liquid Pressure Too high Liquid Pressure Too Low Suction Pressure Too High Suction Pressure Too Low Liquid Refrigerant floodback (TXV System) Liquid Refrig. floodback (Cap. Tube System) I. D. Coil Frosting Compressor Runs Inadequate or No Cooling ELECTRICAL Compressor &...
  • Page 11 Service Facts IGN Diagnostic Indicators Flash Codes IGN Diagnostic Indicators Flash Codes Status LED Liteport LED System Lockout: Failed to detect or sustain flame Steady OFF Check Power or Failed Board 2 Flashes Slow Flash Rate Normal, No Call for Heat 3 Flashes Pressure switch problem detected High Limit switch protection device Fast Flash Rate...
  • Page 12 Trane 6200 Troup Highway 01/13 Tyler, TX 75707...

This manual is also suitable for:

4ycy4036b10754ycy4036b1096b