Nokia Customer Care
TX DC Test Points
1
Table 4
shows the Tx DC test points shown in
Table 4: Tx DC Test Points and RF Supply Line Resistance to Ground
Test
Description
Point
1
VIO
2
VR3
3
VR7
4
VR5
5
VR4
6
VR6
7
VR2
8
VR1B
Issue 1 03/2005
Figure 8: Bottom side Tx DC test points
Value
1.8 V
2.78 V (synthesizer)
2.78 V (Rx)
2.78 V (Rx)
2.78 V (Rx)
2.78 V (Tx)
2.78 V (Tx)
4.75 V (Tx)
©2005 Nokia Corporation
2115i/2116/2116i (RH-66)
RF Description and Troubleshooting
4
6
8
Figure
8.
RF Supply Lines Resistance to Ground*
Ω
>1M
to ground
Ω
>500k
to ground
Ω
~500k
to ground
Ω
3.2~5.1
to ground
Ω
4.3k
to ground
Ω
300k
to ground
Ω
7.5k
to ground
Ω
>100k
to ground
Company Confidential
2
3
5
7
9
10
N7100, N7000, UHF PLL
VCTCXO
N7100
N7160, N7100
VCO
N7000
N7000, PA detector
N7000
Page 13