MULTI-PORT IN-LINE FANS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOW-
ING:
1 . Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer at the address or telephone number listed below
the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fueling
equipment to prevent backdrafting. Follow the heating
equipment manufacturer's guideline and safety stan-
dards such as those published by the National Fire
PLAN THE INSTALLATION
Adequate ventilation requires that both intermittent and
continuous contamination be controlled.
Intermittent ventilation must be provided in the bathroom
and kitchen. The bathroom requires 8 air changes per hour.
(Multiply bathroom sq. footage by 1.1 for proper fan sizing).
The kitchen requires a minimum of 150 CFM capacity (71
l/s) when a ducted range hood is used. If a kitchen fan is
used, determine fan capacity by multiplying the room's sq.
footage by 2. All are run intermittently to control pollution at
the source.
Continuous ventilation, while the house is occupied, pro-
vides the flow of fresh air for good indoor air quality.
This ventilator is intended for continuous operation, supply-
ing fresh air to the entire house.
WARNING
Protection Association (NFPA), and the American Soci-
ety for Heating, Refrigeration and Air Conditioning Engi-
neers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust,
etc. off power unit.
3. If ventilator is installed in an unconditioned space
(such as an attic): Surround the ventilator with thermal
insulation - to minimize possible condensation.
4. Please read specification label on product for f u r t h e r
information and requirements.
RECOMMENDED VENTILATOR SIZING
DWELLING SIZE RANGE (Sq. Ftg.)
(include finished basement area)
MODEL
.50 AC/HR*
1500
MP100
2100
MP140
3000
MP200
*AC/HR = Air Changes per Hour. Based on 8' ceilings.
Square Feet x .093 = Square Meters
.35 AC/HR*
.30 AC/HR*
2140
2500
3000
3500
4285
5000

Advertisement

Table of Contents
loading

Summary of Contents for Broan MP100

  • Page 1 (Multiply bathroom sq. footage by 1.1 for proper fan sizing). The kitchen requires a minimum of 150 CFM capacity (71 l/s) when a ducted range hood is used. If a kitchen fan is used, determine fan capacity by multiplying the room's sq.
  • Page 2: Plan The Installation

    Floor Equipment SINGLE-STORY HOME FRESH AIR INLETS DUCTED KITCHEN RANGE HOOD DIFFUSER DIFFUSER DUCTED BATH FAN FRESH AIR INLETS TWO-STORY HOME FRESH AIR INLETS S E C O N D DIFFUSER FLOOR DUCTED BATH FAN FRESH AIR INLETS DUCTED KITCHEN...
  • Page 3: Mount The Ventilator

    INSTALL FRESH AIR INLETS 1. Mount all fresh air inlets in chosen locations during rough-in construction. Follow directions packed with inlets. MOUNT THE VENTILATOR CEILING JOISTS CEILING JOISTS FRAMING 1. Add framing to ceiling joists as shown. 2. Set ventilator in place and screw to framing with screws provided.
  • Page 4: Motor Lubrication

    This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
  • Page 5 VENTILATEUR À PRISE D'AÉRATION MULTIPLE MODÈLES MP100, MP140 & MP200 LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LE RISQUE D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES PERSONNELLES, OBSERVEZ CE QUI SUIT: 1. Utilisez cett e unit é seulement de la fa ç on pr é vue par le fabricant.
  • Page 6 PROJETEZ L' INSTALLATION AIR VICIÉ VENTILATEUR DIFFUSEUR FRAIS CIRCULATION D'AIR DANS UNE INSTALLATION TYPIQUE VENTILATEUR é . Il y a normalement suffisamment Le ventilateur aspire l' air vici d'ouvertures naturelles dans une maison pour laisser p l'air frais de l'ext é...
  • Page 7 INSTALLEZ DES PRISES D'AIR FRAIS 1. Installez toutes les prises d'air frais aux endroits choisis pendant les travaux préparatoires de construction. Suivez les instructions emballées avec les prises d'air. MONTEZ LE VENTILATEUR SOLIVES DE PLAFOND SOLIVES DE PLAFOND SUPPORTS 1. Ajoutez des supports aux solives de plafond tel qu'illustré. 2.
  • Page 8: Pièces De Rechange

    Cette garantie vous donne des droits légaux spécifiques et il se peut que vous ayez d’autres droits qui varient d’un état à un autre. Cette garantie annule toutes les garanties précédentes. Pour le service sous garantie, vous devez (a) aviser Broan, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout défaut dans le produit ou la pièce. Au temps de demander le service sous garantie, vous devez présenter une preuve de la date d’achat original.

This manual is also suitable for:

Mp140Mp200

Table of Contents