Instructions on transportation and storage

1. During transportation or storage, the heat pump water heater shall be packed in the
undamaged package to avoid damage to appearance and performance of the product;
2. During transportation or storage, the heat pump water heater shall be in the upright
position;
3. Under special conditions, this product may be laid down for a short time/distance as
per indication on the side of the package case. The heat pump water heater, after being
laid down for a certain time, shall be kept at upright position for more than 4 hours before
starting up.
The machine shall be kept in the upright position at any time for the best
performance !
Functionings & principles
A low-pressure liquid refrigerant is vaporized in the heat pump's evaporator and passed
into the compressor. As the pressure of the refrigerant increases, so does its
temperature. The heated refrigerant runs through a condenser coil within the storage
tank, transferring heat to the water stored there. As the refrigerant delivers its heat to the
water, it cools and condenses, and then passes through an expansion valve where the
pressure is reduced and the cycle starts over.