Haier HP200M1-U1 Operation And Installation Manual

Haier HP200M1-U1 Operation And Installation Manual

Hide thumbs Also See for HP200M1-U1:

Advertisement

Quick Links

Heat Pump Water Heater
Operation and Installation Manual
Model
HP200M1-U1
HP250M1-U1
SAA-230239-EA
AS/NZS 2712 SMK41331
AS 3498 WMK26822
Please read this manual carefully prior to the
installation and use of this appliance.
The appearance of the water heater given in
this manual is for reference only.
This product must be installed outdoors.

Advertisement

Table of Contents
loading

Summary of Contents for Haier HP200M1-U1

  • Page 1 Heat Pump Water Heater Operation and Installation Manual Model HP200M1-U1 HP250M1-U1 SAA-230239-EA AS/NZS 2712 SMK41331 AS 3498 WMK26822 Please read this manual carefully prior to the installation and use of this appliance. The appearance of the water heater given in this manual is for reference only.
  • Page 2: Table Of Contents

    3. Installation must be carried out by qualified professionals. Do not open the cover or panel unless qualified to undertake this work. Contact Haier Customer Service if service or repair work is required. 4. This appliance must be permanently connected to mains water supply...
  • Page 3 4. This product must be installed outdoors. 5. This product cannot be discarded or scrapped without correct retrieval of the refrigerant. a. If necessary, please contact Haier Customer Service to obtain the correct disposal method. 6. The product must not be stored in an area containing an open flame such as an open fire, gas appliance or...
  • Page 4: Safety Warnings

    Safety warnings – To be followed at all times Interpretation of marks and symbols Failure to follow these instructions may lead to serious malfunctions of the device and danger to the user Instructions marked with this symbol must be followed. Failure to do so may lead to product damage and harm to the user.
  • Page 5 Safety warnings – To be followed at all times The outlet water temperature This appliance must be of a water heater is typically installed with an isolation higher than the temperature switch to the power supply. indicated on the display. This switch must ensure full Ensure that contact to hot disconnection and be in...
  • Page 6 Safety warnings – To be followed at all times Installation, service, or maintenance of this appliance must be carried out by a qualified professional. Failure to adhere to this may result in damage to the appliance or other property, or cause injury. Fit the appliance in accordance with this installation manual.
  • Page 7 Any damage could result in a refrigerant leak. Scrapping and recovery requirements Scrapping must only be carried out by a qualified professional. This professional must safely recover the appliance’s refrigerant before the appliance is scrapped. Contact Haier Customer Service to correctly dispose of this appliance.
  • Page 8: Functioning Principles Of Heat Pump Water Heaters

    Technical specifications Functioning principles of heat pump water heaters Air source heat pump water heaters mainly consist of a compressor, an expansion valve, a filter, an evaporator, a condenser, and a fan. Powered by electricity, the compressor absorbs low-temperature and low-pressure refrigerant gas from the evaporator.
  • Page 9: Technical Specification

    Technical specifications Model HP200M1-U1 HP250M1-U1 Tank Total water capacity 195L 246L Rated voltage/ frequency 220-240V/50Hz 220-240V/50Hz Tank max pressure 700kPa 700kPa Corrosion protection Magnesium rod Magnesium rod Waterproof grade IPX4 IPX4 Performance (20°C/15°C Ambient air temperature, 15°C -55°C water temperature) COP*@ 20°C/15°C...
  • Page 10: Description Of Parts And Components

    Description of parts and components Heat pump layout Display Condensation drain PTR valve PTR valve connection Hot water connection outlet Cold water Inlet Carton contents Part Heat pump Instruction name water heater manual valve Quantity...
  • Page 11 Description of parts and components Exploded view of the heat pump ● Description Description Fan blade Display panel & Cover Diversion air duct Front shell Electrical box cover Rear shell Control panel Compressor capacitance Electrical box Thermal cut-out Electronic expansion valve Decorative cover Four-way valve Waterproof cover...
  • Page 12: Transport And Storage Instructions

    Installation instructions Transporting the appliance During transport or storage, the heat pump water heater should remain in undamaged packaging to prevent damage to the appliance. During long periods of transport or storage, the heat pump water heater must be in an upright position. For short distance transportation (under one hour), this product may be laid down within 1 hour as per indication on packaging.
  • Page 13 Installation instructions Installation dimensions 30° PTR valve unit: mm Model HP200M1-U1 1658 HP250M1-U1 1272 1951...
  • Page 14 Installation instructions Installation clearances Air outlet Display Note: This appliance must be installed in a location where it can be quickly and easily drained and moved to a location with 1000mm clearance above the appliance. This is so the anode to be removed for checking and replacing during the 5 yearly service...
  • Page 15 Installation instructions Plumbing installation WARNING — FOR CONTINUED SAFETY OF THIS APPLIANCE IT MUST INSTALLED, OPERATED MAINTAINED ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTUCTIONS. WARNING — THIS APPLIANCE MAY DELIVER WATER AT HIGH TEMPERATURES. REFER PLUMBING CODE AUSTRALIA (PCA), AND ALL LOCAL REGLATIONS ON ADDITIONAL DELIVERY TEMPERATURE CONTROL MUST BE FOLLOWED.
  • Page 16 Installation instructions Plumbing installation continued The water inlet and outlet pipes must be fitted to as per the labels at the hot and cold-water connections. To avoid damage to the appliance, the inlet water temperature should remain between 10-40°C. Before filling the tank, make sure that the cold-water inlet and hot- water outlet of the appliance are open, along with the farthest hot water fixture are opened.
  • Page 17 Installation instructions Electrical installation CAUTION: In order to avoid inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility (off-peak electrical line).
  • Page 18 Installation instructions Seismic strapping FOR NEW ZEALAND INSTALLS ONLY The Plumbing and Drainage standard (AS/NZS 3500.4) requires all storage water heaters in New Zealand to be installed with seismic restraints to avoid damage or personal injury if a seismic event should occur.
  • Page 19: Commissioning Checklist

    Installation instructions Wiring diagram CN11 CN12 Capacitor Four-way Discharge temperature valve CN13 sensor MAIN BOARD CN10 Defrost temperature White sensor ︳ Ambient temperature Brown sensor White Suction temperature sensor ︳ Black Water tank temperature sensor ( upper) Compressor ︳ CN7/8 CN24 Water tank temperature sensor ( lower )
  • Page 20: Operating Functions

    Description of the icons Operating functions Display Functions & Protections A. Electrical leakage protection This appliance features an electricity leakage protection function. B. Compressor protection When switched on, the appliance will take approximately 3 minutes to start the compressor for heat pump heating. C.
  • Page 21 Description of the icons Symbol Description Power ON/OFF switch Working mode selection Confirming the selection Timer adjustment Boost mode. Heat pump and backup element heat simultaneously for a faster recovery time. Auto mode - Optimised management of the heat pump and backup element for guaranteed comfort )...
  • Page 22 Description of the icons Symbol Description Boost mode. Heat pump and backup element are activated at the same time (only in AUTO mode). Heat pump working icon. Auxiliary electrical heater working icon. When the PV function is turned on, the setting temperature will be automatically adjusted to 65°C,...
  • Page 23 Operating functions...
  • Page 24 Operating functions Installer settings & WIFI connection Factory Adjustment Parameters Description setting range Compressor maximum continuous working time 5-15h - If the maximum continuous working time of the compressor more than Set Time, start auxiliary power. Set the day of the week d1-d7 - Set the day of the week, d1 to d7 for Monday to Sunday, and remember the day of the week.
  • Page 25: Checking And Maintenance

    Check the watertightness of the water connections and piping. Cleaning the fan The fan should be checked for dust annually. If cleaning is required call Haier Customer Service or a qualified professional. Checking and cleaning the evaporator must be completed by a qualified professional.
  • Page 26 Faults and protection Water Quality A breach of this condition may void the warranty in the event of damage caused by water quality exceeding these characteristics. Water supply from an unfiltered water source that may be highly conductive or have a high mineral content may void the system warranty.
  • Page 27: Faults And Protection

    Improper disposal is hazardous to health and environment. You can obtain further information on how to dispose of this product correctly by calling Haier Customer Service.
  • Page 28 New Zealand 0800 424 372 | haier.co.nz Fisher & Paykel Australia Pty Ltd, Level 1, 1 Eden Park Drive, Macquarie Park, NSW 2113. Phone Customer Care: 1300 729 948 Email: customer.care@haier.com.au Fisher & Paykel Appliances Ltd, 78 Springs Road, East Tamaki, Auckland 2013.

This manual is also suitable for:

Hp250m1-u1

Table of Contents