Validate Modulo 16 and Transmit
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the
scanner looks for a Codabar symbol having a "D" start character, adjacent to a
symbol having a "D" stop character. In this case the two messages are
concatenated into one with the "D" characters omitted.
Select Require to prevent the scanner from decoding a single "D" Codabar
symbol without its companion. This selection has no effect on Codabar symbols
without Stop/Start D characters.
Codabar Message Length
Scan the barcodes below to change the message length. Refer to
Length Description
Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
84
A 1 2 3 4 D D 5 6 7 8 A
On
Require
(page 81) for additional information. Minimum and
Minimum Message Length
* Off
Message
Maximum Message Length
HH490 User Guide