7-SEGMENT DISPLAY

SCREEN 0 (Display FAULT CODE)
Setting
No.
1
SCREEN 1 (Display FAULT CODES)
Setting
No.
1
2
3
4
5
6
SCREEN 2 (MONITOR MODE)
Setting
No.
1
Compressor operation time
2
operation code
3
Compressor Reduction Mode
4
% demand
5
Act % demand
6
Requested id CfM
7
Reported id CfM
8
outdoor fAn RPM
9
ta (outdoor Air temperature)
10
td (outdoor discharge temperature)
11
tm (outdoor Coil temperature)
12
tb (outdoor Coil defrost temperature)*
13
tl (outdoor Liquid temperature)
14
Pressure sensor
15
ts (outdoor Suction temperature)
1
*
HP only
Contents
fault code (present)
Contents
fault code (latest)
fault code (2nd)
fault code (3rd)
fault code (4th)
fault code (5th)
fault code (6th)
Contents
1
Notes
Notes
Latest
2nd
3rd
4th
5th
6th
Notes
unit: hr (Multiply by 200)
0: Stop
1: Cooling Start-up
1
2: Heating Start-up*
3: oil Return operation
1
4: Heating operation*
1
5: defrost operation*
6: Cooling operation
0:off, 1: on
unit: %
(Cut off the decimal first place)
unit: %
(Cut off the decimal first place)
unit: CfM (Multiply by 10)
unit: CfM (Multiply by 10)
unit: RPM (Multiply by 10)
unit: f
unit: f
unit: f
unit: f
unit: f
unit: PSi
unit: f
51