9 Voltage Measurement & Waveform Chart
Note:
• Indicated voltage values are the standard values for the unit measured by the DC electronic circuit tester (high-impedance) with
the chassis taken as standard.
Therefore, there may exist some errors in the voltage values, depending on the internal impedance of the DC circuit tester.
• Circuit voltage and waveform described herein shall be regarded as reference information when probing defect point because it
may differ from actual measuring value due to difference of Measuring instrument and its measuring condition and product itself.
9.1.

D-AMP P.C.B.

REF NO.
MODE
1
2
CD PLAY
-21.0
0
STANDBY
-21.0
0
REF NO.
MODE
21
22
CD PLAY
0
0
STANDBY
0
0
Q1004
REF NO.
MODE
E
C
CD PLAY
5.0
5.0
STANDBY
5.0
0
9.2.

LED P.C.B.

REF NO.
Q4000
MODE
E
C
CD PLAY
0
5.0
STANDBY
0
0
9.3.

Waveform Chart

3
4
5
6
7
0
29.5
0
-29.5
0
0
29.5
0
-29.8
0
23
5.0
0
Q1005
B
E
C
B
5.0
0
0
0
0
0
0
5.0
Q4001
B
E
C
B
5.0
5.0
5.0
0
0
0
0
5.0
60Vp-p(1usec/div)
IC5200
8
9
10
11
12
30.0
0
0
-29.5 -29.5 -29.5
29.5
0
0
-29.5 -29.5 -29.8
IC5200
Q1006
E
C
B
0
5.0
0
0
0
5.0
1.1Vp-p(200usec/div)
19
13
14
15
16
17
0
0
29.5 -29.5 -29.5
0
0
29.5 -29.5 -29.5
Q1007
E
C
B
E
0
3.3
0
0
0
3.3
0
0
SH-FX71GC/GN D-AMP P.C.B.
SH-FX71GC/GN LED DRIVE P.C.B.
18
19
20
0
29.5
0
29.5
Q1008
C
B
3.3
0
3.3
0

Hide quick links: