Download Print this page

ADTRAN NetVanta Serial Dial Backup Interface Module (DIM) none Quick Start Manual

Netvanta serial dial backup interface module (dim)

Advertisement

Quick Links

®
NetVanta Serial Dial Backup Interface Module (DIM)
Quick Start Guide
SLOT 1 NET/D BU
WAN-T1
DSX-1
DBU
WAN-DDS
DBU
S
PECIFICATIONS
Features
5-pin RS-232 interface via host RJ-45 DBU connector
Modem flow control support via CTS
Communication with external modem via AT commands
Compliance
FCC Part 15 Class A, EN 55022 Class A, EN 55024
EN 61000-3-2, EN 61000-3-3
IEC 60950, EN 60950, UL/CUL 60950, AS/NZS 60950
Physical
Dimensions: 2.3-inch W x 2.75-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
An RJ-45 to DB-9 adapter cable (P/N 1200887L1) is
required to connect to the external modem.
NetVanta modules should be installed only in
NetVanta Series products.
Quick Start Guide, 61200886L1-13B, July 2006
LAN
CONSOLE
Technical Support 1-888-4ADTRAN (1-888-423-8726)
For more detailed documentation, visit us online at www.adtran.com.
I
I
NSTALLATION
NSTRUCTIONS
1.
Remove power from the base unit.
2.
If the Network Interface Module (NIM) is already in the NetVanta
chassis, release the pins at both edges of the NIM faceplate and slide
the module out of the chassis.
3.
Carefully align the P1 connector on the NIM with the J1 connector on
the Serial DIM. Using only fingertip pressure so that neither circuit
board bends or flexes, ensure that the connectors are firmly seated.
Secure the Serial DIM to the NIM using the screws and standoff posts
supplied.
4.
Slide the NIM with the Serial DIM attached into the NetVanta option
slot until the NIM is firmly seated against the chassis.
5.
Secure the pins at both edges of the NIM.
6.
Connect the cables to the associated device(s)
7.
Complete installation of the base unit.
For NetVanta modules with outside plant
connections, ensure that all cables are
removed from the module before installing or
removing it from the NetVanta chassis.
S
DBU C
ERIAL
ONNECTION
Pin
1, 2
3
4
5
6
7
8
Important: For additional details on product
features, specifications, installation, and safety, refer
to the appropriate Hardware Installation Guide on
the ADTRAN OS System Documentation CD
shipped with the base unit and available online at
www.adtran.com.
P/N 1200886L1
P
INOUTS
Name
Unused
CTS
TXD
RXD
GND
DCD
Unused
Copyright © 2006 ADTRAN, All Rights Reserved

Advertisement

loading

Summary of Contents for ADTRAN NetVanta Serial Dial Backup Interface Module (DIM) none

  • Page 1 NetVanta modules should be installed only in NetVanta Series products. Quick Start Guide, 61200886L1-13B, July 2006 For more detailed documentation, visit us online at www.adtran.com. NSTALLATION Remove power from the base unit. CONSOLE...
  • Page 2 Use the no version of this command to turn on the interface and allow it to pass data. Quick Start Guide, 61200886L1-13B, July 2006 For more detailed documentation, visit us online at www.adtran.com. Technical Support 1-888-4ADTRAN (1-888-423-8726) P/N 1200886L1...

This manual is also suitable for:

1200886l1