Storage temperature
Ambient temperature
for operation
5

Operation

TE 3-M
Changing the quick-release chuck
Fitting the side handle
CAUTION
Risk of injury! The depth gauge, if fitted but not used, might hinder the operator.
▶ Remove the depth gauge from the tool.
CAUTION
Risk of injury! Loss of control over the rotary hammer drill.
▶ Check that the side handle is fitted correctly and tightened securely. Check that the clamping
band is engaged in the groove in the tool.
Fitting/removing the drill bit or other accessory: SDS quick-release chuck
Use of unsuitable grease may cause damage to the product. Use only the
recommended grease supplied by Hilti.
TE 3-M
Fitting/removing the drill bit, chisel or other accessory: Three-jaw chuck
Drilling without hammering
Screwdriving
Drilling with hammering action (hammer drilling)
Setting the chiseling function
Chisel positioning
CAUTION
Risk of injury Loss of control over the chisel direction.
▶ Do not operate the tool when the selector switch is set to "Chisel positioning". Turn the
function selector switch until it engages in the "Chiseling"
Forward / reverse
Adjusting the depth gauge
Fitting the dust collection module for overhead work
Pressing/locking the control switch
Replacing the dust shield
6
Care of the product
▶ Keep the product, especially its grip surfaces, clean and free from oil and grease. Do not use
cleaning agents containing silicone.
▶ Never operate the product when the air vents are blocked. Clean the air vents carefully using a dry brush.
Do not allow foreign objects to enter the interior of the product.
▶ Clean the outside of the product at regular intervals with a slightly damp cloth. Do not use a spray, steam
pressure cleaning equipment or running water for cleaning.
6
English
Printed: 20.12.2018 | Doc-Nr: PUB / 5245520 / 000 / 04
TE 3­M
−4 ℉ ... 158 ℉
(−20 ℃ ... 70 ℃)
1 ℉ ... 140 ℉
(−17 ℃ ... 60 ℃)
TE 3­C
−4 ℉ ... 158 ℉
(−20 ℃ ... 70 ℃)
1 ℉ ... 140 ℉
(−17 ℃ ... 60 ℃)
position.