24/33
Installation and Removal
Fig. 10-6: Mounting the connector with shield and support bracket
10.6 System power supply connection
A power on/off switch or circuit breaker is not part of the system housing. You
must implement the following in the installation.
A switch or circuit breaker must be included in the installation.
●
The switch or circuit breaker must be placed at a suitable location and must
●
be easy accessible.
The switch or circuit breaker must be marked as the disconnecting device for
●
the system housing power supply.
10.7 Configuration
The left side of the system housing is the side where the "24V System" power
supply connector is located.
In the system housing the slot on the leftmost side is called "MCU" and is a slot
dedicated for the installation of the Motion Control Unit (MCU).
The adjacent slots at the right side of the MCU module in the module holder are
drive slots called "DRV0" and "DRV1" for the drive modules type NYM04.1-2PW-
NNNN-NY4120/10.
Bosch Rexroth AG R911383227_Edition 04
G
NYCe 4000 Linear motion control sys-
F
tem