GE PSB42LSRBV Manual page 52

Table of Contents

Advertisement

 Measure 120VAC at CN07 pins 6 & 8 for
Auger Motor operation.
 To check Auger Motor, measure 3.7 at
CN07 pins 6 & 8.
 The cube motor is in series with the
thermal protector inside the auger motor.
 Measure 120VAC at CN07 pins 6 & 7 for
Cube Motor operation.
 To check Cube Motor, measure 2K at
 To check Cube Motor, measure 2K at
CN07 pins 6 & 7.
g
GE imagination at work
Auger & Cube Motor Circuit
GE Profile 42-48 Refrigerators (4/1/05)
GE CONFIDENTIAL & PROPREITARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
Copyright 2007 General Electric Company – 12/14/2009