Function/group
Item
System
Application
Integration
Programming
Interface
Intelligent Video
Alarm triggers
Alarm events
Video buffer
Video access from
web browser
Installation,
management and
maintenance
General
Casing
Processors, memory
Power
Connectors
Local storage
Operating conditions • Operating conditions camera unit
Approvals
AXIS Q6032-E - Technical Specifications
Specification
Open API for software integration, including VAPIX® from Axis
Communications*, AXIS Media Control SDK*, event trigger data in video
stream
Quality of Service (QoS) layer 3, DiffServ Model
Embedded Linux operating system
*Available at www.axis.com
Video motion detection, auto-tracking
Intelligent video
PTZ position
File upload via FTP, HTTP and email
Notification via email, HTTP and TCP
PTZ position
Video recording to local storage
56 MB pre- and post alarm
• Camera live view
• Video recording to file (ASF)
• Sequence tour for up to 20 Axis video sources,
• Windows Vista, XP, 2000, 2003 server
• DirectX 9c or higher
• For other operating systems and browers see www.axis.com/techsup
• AXIS Camera Management tool on CD and web-based configuration
• Configuration of backup and restore
• Firmware upgrades over HTTP or FTP, firmware available at www.axis.com
Metal casing (Aluminum)
Acrylic (PMMA) clear dome cover pre-mounted to casing,
Sunshield (polycarbonate)
IP66 rated
ARTPEC-3, 128 MB RAM, 128 MB Flash
• Camera: High Power over Ethernet, max 50W
• Midspan (included):
AXIS T8124 High Power over Ethernet Midspan 1-port
100-240V AC, max 60W
• RJ-45 Ethernet 10BASE-T/100BASE-TX
• IP66-rated RJ45 connector kit included
SD/SDHC memory card slot (card not included)
-40 to 50 °C (-40 to 122 °F)
Artic Temperature Control enables camera start-up at temperatures as low
as -40 °C (-40 °F)
• Operating conditions midspan
Full power 60W: -10 to 45 °C (heater in camera unit active)
Half power 30W: -10 to 55 °C (heater in camera unit inactive)
• Humidity up to 93% RH (non-condensing)
• EN 55022 Class B,EN 55024,EN 61000-3-2,EN 61000-3-3
• EN 61000-6-1,EN 61000-6-2, FCC Part 15 Subpart B Class B
• VCCI Class B
• C-tick AS/NZS CISPR22
• ICES-003 Class B, EN 60950-1
• Midspan: EN 60950-1, GS, UL, cUL, CE