(8) Flap control

Control the flap by AIR FLOW
(a) Flap
Each time when you press the AIR FLOW
(Flap stopped)
  Angle of Flap from horizontal
Remote control
display
COOL , DRY, FAN
HEAT
(b) Swing
(i) Swing flap
Flap moves in upward and downward directions continuously.
In HEAT operation
Approx.44°
Approx.5°
(c) Memory flap (Flap stopped)
When you press the AIR FLOW button once while the flap is operating, it stops swinging at the position. Since this angle is
Approx. 45°
memorized in the microcomputer, the flap will automatically be set at this angle when the next operation is started.
(d) When not operating
Approx. 75°
The flap returns to the position of air flow directly below, when operation has stopped.

(9) Air outlet selection

(a) AIR SELECTION button can switch between the combination of upper and lower air outlets and upper air
outlet. Not operable while the air-conditioner is OFF.
(i) Each time the AIR SELECTION button is pressed. The combination of the
upper and lower air outlets and the upper air outlet can be switched.
(ii) When the upper air outlet is selected, AIR OUTLET SELECTION light on
the unit display area will light green.
Upper and lower air outlets
AIR OUTLET SELECTION
light : OFF
(b) Auto air outlet selection
(i) COOL, DRY operation
1) In case both lower and upper outlets operation is selected in Cooling or Dry
operation, both outlets will be kept for sixty minutes after the start or until
indoor temperature is below the setting point. And then the air outlet will change
to the upper outlet. That state will be maintained until switch is turned off.
2) In case both outlets operation with auto fan speed mode is selected, the upper
outlet will be kept for ten minutes after the start or until indoor temperature is
close to reaching the setting point . And then the air outlet will change to both
outlets in order to spread comfort air to every corner.
 
(UP/DOWN) button on the wireless remote control.
 
(UP/DOWN) button the mode changes as follows.
Approx. 60°
Approx. 50°
Approx. 44°
Approx. 32°
In COOL, DRY, FAN operation
Approx.60°
Approx.12°
Approx.
Approx. 60°
AIR OUTLET SELECTION
light : ON
(Swing)
Approx. 38°
Approx. 21.5°
Approx. 21.5°
Approx. 12°
Upper air outlet
5
-
-
'20 • SRF-SM-311
Approx. 12°
Approx. 5°
AIR SELECTION button