Advertisement

Quick Links

SlimPAR PRO
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet Slim PAR PRO Pix

  • Page 1 SlimPAR PRO User Manual...
  • Page 2: Table Of Contents

    PAR P 1. Before You Begin ............... What Is Included ................... Unpacking Instructions.................. Claims ..........................Text Conventions ..................Symbols ......................Disclaimer ..................... Safety Notes....................FCC Compliance................... 2. Introduction ................Product Overview..................Product Dimensions ..................3. Setup ................... AC Power ...................... Fuse Replacement ......................
  • Page 3: Slimpar Pro Pix

    Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetdj.com.
  • Page 4: Safety Notes

    EFORE EGIN Safety Notes • Always connect the product to a grounded circuit to avoid the risk of electrocution. • Always disconnect the product from the power source before cleaning or replacing the fuse. • Avoid direct eye exposure to the light source while the product is on. •...
  • Page 5: Introduction

    NTRODUCTION 2. Introduction Product Overview Display screen Microphone Safety loop Menu buttons 5-pin DMX in/out 3-pin DMX Power in/out in/out Bracket adjustment knob IR sensor Mounting bracket SlimPAR Pro Pix User Manual Rev. 1 Page 3 of 20...
  • Page 6: Product Dimensions

    NTRODUCTION Product Dimensions 11.4 in 290 mm 12.3 in 313 mm 4.3 in 110 mm Page 4 of 20 SlimPAR Pro Pix User Manual Rev. 1...
  • Page 7: Setup

    The power linking diagram corresponds to the North American version of the product ONLY! If using the product in other markets, you must consult with the local Chauvet distributor, as power linking connectors and requirements may differ in your country or region.
  • Page 8: Mounting

    The bracket adjustment knobs allow for directional adjustment when aiming the product to the desired angle. Only loosen or tighten the bracket knobs manually. Using tools could damage the knobs. Mounting Diagram Mounting clamp (such as CLP-15 or CLP-15N from Chauvet) Mounting bracket Safety cable (such as CH-05 from Chauvet) Bracket...
  • Page 9: Operation

    PERATION 4. Operation Control Panel Operation To access the control panel functions, use the four buttons located underneath the display. Please refer to Product Overview to see the button locations on the control panel. Button Function <MENU> Press to find an operation mode or to back out of the current menu option <UP>...
  • Page 10: Configuration (Dmx)

    PERATION Configuration (DMX) The SlimPAR Pro Pix works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website: www.chauvetdj.com. DMX Personality and Starting Address When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses.
  • Page 11 PERATION Channel Function Value Percent/Setting Blue 10 000  255 0–100% Red 11 000  255 0–100% Green 11 000  255 0–100% Blue 11 000  255 0–100% Red 12 000  255 0–100% Green 12 000  255 0–100% Blue 12 000 ...
  • Page 12: 26Ch

    PERATION 26Ch Channel Function Value Percent/Setting Master dimmer 000  255 0–100% Red 1 000  255 0–100% Green 1 000  255 0–100% Blue 1 000  255 0–100% Red 2 000  255 0–100% Green 2 000  255 0–100% Blue 2 000 ...
  • Page 13 PERATION Channel Function Value Percent/Setting Ring blue 000  255 0–100% 000  015 No function Ring strobe 016  255 Slow to fast 000  005 No function 006  016 Ring auto program 1 017  027 Ring auto program 2 028 ...
  • Page 14: 12Ch

    PERATION 12Ch Channel Function Value Percent/Setting Master dimmer 000  255 0–100% Red 1 000  255 0–100% Green 1 000  255 0–100% Blue 1 000  255 0–100% Amber 000  255 0–100% White 000  255 0–100% 000 ...
  • Page 15 PERATION Channel Function Value Percent/Setting 000  005 No function 006  016 Ring auto program 1 017  027 Ring auto program 2 028  038 Ring auto program 3 039  049 Ring auto program 4 050  060 Ring auto program 5 061 ...
  • Page 16: Configuration (Standalone)

    PERATION Configuration (Standalone) Set the product in one of the standalone modes to control without a DMX controller. Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.
  • Page 17: Strobe

    S.100 – Sound strobe Press <ENTER>. IRC-6 Infrared Remote Control The SlimPAR Pro Pix is compatible with the IRC-6 infrared remote control from Chauvet. To activate IR mode, follow the instructions below: Press <MENU> repeatedly until SET shows on the display.
  • Page 18: Master/Slave Mode

    PERATION Master/Slave Mode The Master/Slave mode allows a single SlimPAR Pro Pix product (the “master”) to control the actions of one or more SlimPAR Pro Pix products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in Standalone or with the IRC-6, whereas the slave products will be set to operate in Slave mode.
  • Page 19: Maintenance

    AINTENANCE 5. Maintenance Product Maintenance Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
  • Page 20: Technical Specifications

    ECHNICAL PECIFICATIONS 6. Technical Specifications Dimensions and Weight Length Width Height Weight 11.4 in (290 mm) 4.3 in (110 mm) 12.3 in (313 mm) 9.8 lb (4.5 kg) Note: Dimensions in inches rounded to the nearest hundredth. Power Power Supply Type Range Voltage Selection Switching (internal)
  • Page 21: Returns

    Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number. Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
  • Page 22: Contact Us

    ONTACT Contact Us General Information Technical Support Chauvet World Headquarters Address: 5200 NW 108th Ave. Voice: (844) 393-7575 Sunrise, FL 33351 Fax: (954) 756-8015 Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com Fax: (954) 929-5560 Toll Free: (800) 762-1084 Website: www.chauvetdj.com Chauvet Europe Ltd...

Table of Contents