Avaya M770 Ethernet Known Issues
The following is a list of known issues for specific code revisions of the Avaya M770
Ethernet. This list contains the issues with possible "workarounds" where available. For
more information, please refer to the Release Notes related to the relevant released
version.
Avaya M770 Ethernet, Version v2.x.x
Product
Version STR
M770-M2-1000F
2.0
M770-MSPX
2.5
M770
2.5
M770
2.5
M770-MSPX
2.5
M770
2.5
5288 If both ports main and redundant ports will encounter link failure,
then the secondary port will become the active link.
6514 MSPX does not block STA enabling when S/W redundancy is
enabled. The user will be warned only after he will invoke S/W
Redundancy command, define pair of redundant ports and click on
the 'apply' button.
7163 Configuration: P770 hub with 14 modules. Reset the device may
ended up with M24-10T module that was not registrated in M-SPX.
A consecutive reset will solve the problem.
6913 In some rare condition: Network that supports more then 15 hundreds
MAC addresses during heavy traffic while the master agent is busy
with specific tasks such as STP configuration change etc. a
momentary leakage of several frames between different Vlans where
noticed.
6771 M-SPX may be reset in a very loaded M770, 10 modules or higher,
while IDS is in 'ON' position. This is due to a long registration
process.
6917 The <<Backspace>> key on the keyboard does not clear the
characters from the screen (CLI mode).