10
Electrical connection
DANGER
Risk of electric shock!
® Risk of injury or death (if
operating voltage is higher
than safe extra low voltage).
Electrical connection only to
G
be carried out by a qualified
electrician.
Disconnect the cable from
G
the power supply before
making the electrical
connection.
Connect the protective earth
G
conductor.
1. Guide the cable through the locking
screw 1, pressure ring 2, seal 3 and the
housing of the plug 4.
Electrical connection
2. Connect the cable to the relevant
terminals on the terminal block.
Different connections are
available depending on plug
type and voltage.
2
Connection to terminal block
2026
Item
1
2
3. Push the terminal block into housing
of plug 4 (to DIN EN 175301-803 A,
previously DIN 43650) until it audibly
clicks into position.
4. Ensure that the cable is not caught.
5. Tighten locking screw 1 of plug 4.
6. Fit plug 4 and seal 6 on connector plug 7.
7. Tighten fi xing screw 5 with a torque of
4
approx. 0.6 Nm.
3
2
1
1
16 / 20
Connection
Supply voltage (+)
Supply voltage
Protective earth conductor
4
2
6
3
7
7
Connecting the plug
If the torque is too high the
thread may be stripped.
1 5
Tightening the fi xing screw