Tx DC Test Points

Table 1 shows the Tx DC test points shown in Figure 6
Test Point Description
1
PA_ON
2
PA_R1
3
LOCK_DET
4
TX_AGC
5
Tx IQ in
6
Tx_on
Figure 6: Tx DC test point
3.08V for PA turning on, 0V for turning off
2.16V for high gain mode,1.6V for low gain mode
3.08V for Lock, 0 V for unlock
1.92V for 5dB, 2.16V for 15dB, 2.4V for 25dB.
0.8 V With oscilloscope: 500 mV p-p
2.8 V
Table 1: Tx DC Test Points