  • Page 1 Namco Ozone Machine OZ-1400 USER MANUAL CAUTION: Read manual carefully for proper installation and operation.
  • Page 3: Table Of Contents

    CONTENTS Getting Started 1.Specifications ....................3 2.Product Features....................3 3.Introduction ...................... 4 4.Applications ...................... 5 How To Use 5.Quick Start Guide ..................... 6 6.Operating ......................6 Care And Troubleshooting 7.Replacing the ozone plate ................6 8.Replacing the Fuse ..................7 9.Troubleshooting ....................
  • Page 4: Specifications

    1. SPECIFICATIONS Model: OZ-1400 Rated Voltage: USA market: AC 100~110V/60Hz; Power Consumption: 180W Air Volume: Max 106 CFM(3 m /min) Ozone Plates 90X110mm, 2pcs ceramic ozone plate Active Oxygen(on): 14,000mg/H Sound Level (DB): 45DB Product Size (mm): D 285 x W 166 x H 280 mm Gross Weight: 5.3KG...
  • Page 5: Introduction

    3. INTRODUCTION The Commercial Air Purifier is designed to remove odors in unoccupied spaces. The unit has a timer that will enable it to run for a maximum duration of 3 hours. The timer will then shut the commercial air purifier off. You should allow 40 minutes before returning to the treated area.
  • Page 6: Applications

    (Back View) Part Name Function Fuse Holder Houses removable fuse. (Spare fuse included, 2 Amp, 0.79 inch in length) Power Cord 110~120V or 220~240V grounded cord(unless otherwise) 4. APPLICATIONS  For home use: Air sterilizer, living room. Kitchen. Bathroom, pet room ...
  • Page 7: Quick Start Guide

    5. QUICK START GUIDE  When placing the device, set it on top of something solid to give it a steady base and prevent it from tipping over.  Make sure no humans, animals, pets are present in the area before starting the treatment ...
  • Page 8: Replacing The Fuse

     How to replace a plate:  Turn the unit off and unplug from outlet.  Use a screw driver to unfasten cover screw and remove cover.  Pull ceramic plate out of ozone generator module.  Install ceramic plate as shown in above figure (be careful not to drop the plate).
  • Page 9: Troubleshooting

    If these solutions don’t fix your problem, please contact your authorized distributor for a repair or replacement. 10. SERVICE AND WARRANTY The commercial air purifier comes with 1 Year Limited Warranty. Namco Manufacturing, Inc 9034 Long Point Rd. Bldg B, Houston,TX 77055 Tel: 713-932-8293 Fax: 713-932-9254 TOLL FREE: 1-800-634-5816...
  • Page 10: Warranty Card

    11. WARRANTY CARD To activate warranty you must return this card within 30 days of purchase. ---------------------------------------------------------------------------------------------- --------------- FOR YOUR RECORDS Please record the model and serial number below, for easy reference, in case of loss or theft. These numbers are located on the back panel of your air purification unit.