2-1-3. Starting a PR Board Adjustment
Software
1. Installation of PR board adjustment software
(1) Start PC.
Copy executable file "Camera adjustment.exe" from
CD-ROM of an PR board adjustment software to any
folder of PC.
(2) Create the shortcut "Camera adjustment.exe" in a
desktop.
2. Connection
Connect each equipment referring to the connection
diagram in Section 2-1-2.
3. Setting of camera
(1) Turn on the power of each equipment.
(2) Start a "Camera adjustment.exe".
(3) Check that the IP address of "Enter IP address of SNC-
CS10/11" in the upper left of the adjustment window
is "192.168.0.100". If not, type the IP address
(192.168.0.100).
(4) Click the [Connect] button on the adjustment
window.
SNC-CS10/CS11

2-2. Adjustment

n
Perform the adjustment in Sections 2-2-1 to 2-2-5
continuously.

2-2-1. Initialization of EEPROM

1. Display the adjustment window referring to Section 2-
1-3.
2. Click the [EEPROM|initialize] button.
3. Check that "EEPROM Initialize OK" is displayed in
the state display message box.
If not, quit the PR board adjustment software and
perform the procedure from step 1 again.

2-2-2. CCD Defect Correction

1. Close the lens iris.
2. Click the [White|noise|compensation] button.
"White noise compensation finished" is displayed in
the state display message box. (It takes approx. 2
minutes before the message is displayed.)