Download Print this page

BW Technologies GasAlertClip Instruction Sheet page 2

2 year gas detector

Advertisement

Display Features
A
Maximum exposure under alarm
B
High and low alarm setpoints
C
Self-test status
D
Gas monitored
B E
Alarm condition
F G
Life-remaining clock
A G
Time since maximum exposure
Life-Remaining Clock
The life-remaining clock indicates how much longer the detector will
operate. The display shows the countdown of remaining months, then days,
and then hours.
Gas Alarm Setpoints (factory standard)
Model
Low Alarm Setpoint
GasAlertClip O
19.5%
2
GasAlertClip CO
35 ppm
GasAlertClip H
S
10 ppm
2
GasAlertClip SO
5 ppm
2
Note: May be equipped with customer specified alarm setpoints. Press the
test button to display alarm setpoints at any time.
Gas Alarms
Low Gas Alarm
Display
Audible Alarm
Slow beeps
(1 beep every
2 seconds)
Slow vibrations*
High Gas Alarm
Display
Audible Alarm
Fast beeps
(1 beep every
second)
Fast vibrations*
*Vibrator models only.
When gas levels return to the acceptable range, the gas alarm stops.
Note: The life of the battery decreases rapidly under alarm conditions.
Maximum Gas Exposure
The detector records the maximum gas exposure under alarm condition,
High Alarm Setpoint
and begins calculating the number of hours since the maximum exposure
23.5%
occurred.
200 ppm
For each gas level further from the acceptable range, the detector resets the
15 ppm
maximum gas exposure to the new level and resets hours to 0. After
24 hours of gas reading in the acceptable range, the detector resets both
10 ppm
values to 0.
Viewing Maximum Gas Exposure
Press the Test button within 24 hours of receiving a gas alarm.
If the display shows
1.
The low and high alarm setpoints:
Visual Alarm
Slow flashes
(1 flash every
2 seconds)
2.
The maximum gas exposure and the hours since exposure:
Visual Alarm
Fast flashes
(1 flash every
If the display shows Test when the button is pressed, the display
second)
shows the gas exposure information at the end of the self-test.
For exposures above the measuring range, the display shows OL.
u
, the detector tells you:

Advertisement

loading

This manual is also suitable for:

Gasalertclip o2Gasalertclip coGasalertclip h2sGasalertclip so2Ga24a-h-elGa24a-m-el ... Show all