Sony DVS-7200A Maintenance Manual page 79

Digital video switcher
Hide thumbs Also See for DVS-7200A:
Table of Contents

Advertisement

2. Tool cable for testing communication system
Required in the "Communication test" menu.
(1) Three tool cables for testing the RS-422A communication system
These tool cables are used to connect the "SWITCHER" and "DME" , "REMOTE 1" and "REMOTE
2" , "REMOTE 3" and "REMOTE 4" connectors on the connector panel. These tool cables which
are shorted the two D-SUB 9-pin male connectors as shown below.
Pin No.
1
2
3
4
5
6
7
8
9
(2) One tool cable for testing the RS-232C communication system
This tool cable is used to connect the "TERMINAL 1" and "TERMINAL 2" connectors on the
connector panel. This tool cables which are shorted the two D-SUB 9-pin male connectors as shown
below.
Pin No.
1
2
3
4
5
6
7
8
9
3. DVS-7200A
Required in "Timer & Int. test" menu.
DVS-7200AE MMP1
Signal name
FG
RX-A
TX-B
GND
-
GND
RX-B
TX-A
-
Signal name
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI
3-3-1. Tools and Equipment Required for Troubleshooting
Pin No.
Signal name
1
FG
2
RX-A
3
TX-B
4
GND
5
-
6
GND
7
RX-B
8
TX-A
9
-
Pin No.
Signal name
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
3-3. Troubleshooting (BKDS-7015)
3-11

Advertisement

Table of Contents
loading

Table of Contents