11.
SAFETY DEVICES
Circuit protection
Fan motor protector
Compressor protection
High pressure protection
Low pressure protection
Protection form
Current fuse
(Filter printed circuit board)
Current fuse
(Main printed circuit board)
Thermal protector
Thermal protection program
(Compressor temp.)
Thermal protection program
(Discharge temp.)
Pressure switch
Pressure sensor
- (02 - 14) -
Model
AO A45LC
10A 250V, 3.15A 250V
3.15A 250V
OFF : 150±15°C
ON : 120±15°C
OFF : 108°C
ON : 80°C
OFF : 110°C
ON : After 7 minutes
OFF : 4.2±0.1MPa
ON : 3.2±0.15MPa
OFF : 0.12MPa
ON : 0.15MPa
AO A54LC