Msi/Plessey - Argox AS-8000 Instruction Manual

Wireless imager
Hide thumbs Also See for AS-8000:
Table of Contents

Advertisement

MSI/plessey

Read: Format
Data Digits
(Variable)
Checksum Verification: The MSI/Plessey has one or two
optional checksum digits. The checksum is presented 3
kinds of method Mod10, Mod10/10 and Mod 11/10. The
checksum1 and checksum2 will be calculated as the sum
module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Program
Option Bar Code
Option
Disable
Enable
Read
Disable
Mod 10
Checksum
Mod 10/10
Verification
Mod 11/10
Checksum1
Checksum2
(Optional)
(Optional)
Alphanumeric
Entry
00
01
00
01
02
03
87

Hide quick links: