External entry panel illumination level adjustment. During the call button programming of any internal receiver the external entry
LED
panel illumination level can be adjusted up or down (with the handset lifted if present).
DATI
Pressing the "self-connection
level is to be adjusted to be activated. At this point, by means of the previously assigned call button (by call button or DNA) the il-
lumination level can be either incremented or decremented.
CN2

Initial programming with MULTIPLE entry panels

1
B
M3
A A
M2
C
E
In the case that the call buttons are ONLY located on the ADDITIONAL PUSH BUTTON PANELS, proceed as indicated in
NOTE on page 7.
G
H
" button on the internal receiver causes the external entry panel camera for which the illumination
If an ETI/XIP LAN network server is present within the installation then before proceeding with the pro-
gramming described above the CN2 connector (VA/08 connector) must be disconnected and the three
M4
jumpers inserted as shown in the diagram. Proceed with the programming as described. Once completed
reconnect the CN2 connector and remove the three jumpers.
Accessing programming. Press the PROG key on the power supplier 1 until the
PROG
PROG LED turns on. If the PROG LED turns off suddenly, this indicates a malfunction in
the connection between the power supplier and the entry panel. Check the connections
and return to programming.
The entry panel LEDs turn on as shown in the figure 2. Wait 5 seconds for the self-test
to be completed and then continue as described below.
+D – +V3– +V4 –
M3
Programming the call keys. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release
entry panel, press the call key to associate with the internal extension H: an acoustic
signal will confirm that the setting was stored. Hang up the receiver again, if necessary
j and continue, repeating the same operations for the other extensions. The operation
may only be performed from the entry panel with the LED
change the entry panel from which the call programming is performed, press one of
the first 4 call key positions for at least 3s (or press key 1 followed by key
panels with DNA).
Exiting programming. Briefly press the PROG key on the power supplier I: the PROG
LED and entry panel LEDs will turn off. NOTE. If no action is performed, the procedure
will automatically end after 30 minutes.
Programming the entry panel camera. When programming the call buttons, the
camera's "visual field" can be adjusted as previously described.
Programming key type. Press the first key on the entry terminal
3 until the LED
stops flashing as does the backlighting LEDs
4. Repeat the operation on all entry panels to be programmed
4 E: at the end, the signals will assume the configuration F.
D
F
and AUX2 G buttons. On the
off (PE1 in fig.F): to
for entry.