ADTRAN D4-U-RPM Installation & Maintenance

U-repeater powering module

Advertisement

Quick Links

PRACTICES
Contents
Paragraph
1. General ............................................................ 1
Figure 1. ADTRAN D4 U-RPM ......................................... 1
2. Installation ....................................................... 2
Figure 2. U-RPM Application ........................................... 2
Table A. U-RPM Option Selections ................................. 2
3. Connections .................................................... 2
Figure 3. Connector Pin Assignments ........................... 3
Figure 4. U-RPM Option Locations ................................. 3
4. Maintenance .................................................... 3
5. Warranty And Customer Service .................. 3
1.0
GENERAL
1.01
This section provides installation and
maintenance
information for the ADTRAN U-Repeater
Powering Module (U-RPM), Part Number: 1100022L1.
Figure 1 shows the front of the unit. Figure 2 represents
a generic module application. Figure 3 shows the
connector pin assignments for the U-RPM. The unit's
part number and basic features are:
Part
Equipment
Number
U-Repeater
1100022L1
Powering
Module
(U-RPM)
1.02
This practice has been reissued to reflect the
addition of a field selectable powering option in
Paragraph 2.04 and Figure 4 and the latest CLEI
designation. Issue 3 adds a new Sales telephone number.
®
WECO is a registered trademark of AT&T Technologies
61100.022L1-5C
MODEL U-RPM
D4-U-RPM
U-REPEATER POWERING MODULE
INSTALLATION/MAINTENANCE
Page
Features
Repeater Powering for
ADTRAN ISDN mid-point loop
repeater; Loop resistance fault
indicator; Class A2 or Class A3
operation.
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
FIGURE 1. ADTRAN D4 U-RPM
1.03
The U-RPM is a channel plug-in used in the
ADTRAN GPC-1 or AD4-24 Shelves or the
WECO
®
D4 channel bank, to provide sealing current
power for the ADTRAN ISDN mid-point loop repeater.
1.04
The U-RPM provides three functions for the
ADTRAN ISDN mid-point loop repeater. These
functions are:
1.
The D4-U-RPM receives -48 VDC power
from the facility power source and sends
constant 85 mA of sealing current down
the loop to power the U-Repeater.
2.
A passive customer data flow is allowed
through the D4-U-RPM.
3.
The D4-U-RPM monitors the line for
excessive resistance or open conditions.
SECTION 61100022L1-5
Section 61100022L1-5
Issue 3, April 1992
CLEI Code # DDRPG701_ _
PAGE 1

Advertisement

loading

Summary of Contents for ADTRAN D4-U-RPM

  • Page 1 ADTRAN GPC-1 or AD4-24 Shelves or the WECO ® D4 channel bank, to provide sealing current power for the ADTRAN ISDN mid-point loop repeater. 1.04 The U-RPM provides three functions for the ADTRAN ISDN mid-point loop repeater. These functions are:...
  • Page 2 Class A2 ( 80 V) or may be optioned for Class A3 (0 V to -140 V) operation, using the 22 AWG jumpers provided with the unit, ADTRAN Part Number: 3336.008. See Figure 4 for option locations and Table A for the option settings.
  • Page 3 ADTRAN. WARRANTY AND CUSTOMER SERVICE 5.01 ADTRAN will replace or repair this product within five (5) years from the date of shipment if it does not meet its published specifications or fails while in service.