1. Filter dryer to be applied
1) The filter dryer (one is shipped with each refrigeration unit) is a standard component.
2) In the case of replacement, use the same filter dryer shown below as the standard
component.
Refrigeration Unit
Model No.
OCU-CR200VF5
You must not use a filter dryer for HFC refrigerant under any
Caution
circumstances as it does not meet the pressure requirement.
2. Filter dryer attachment
1) The filter dryer has an expanded tip on both ends.
2) Do not remove the filter dryer cap until immediately before use.
3) Connect the filter dryer to the liquid line between the refrigeration unit outlet (the high
pressure service valve) and the evaporator by brazing.
4) During brazing operation, protect the filter dryer from heat by covering it with wet cloths, etc.
Filter dryer Part No.
D-152T
Cap
280mm
19
Filter dryer Type
CO-082-S
Connection
Diameter
 6.35 mm