Minimum Clearance To Combustible - Napoleon Altitude X Series Installation Manual

Hide thumbs Also See for Altitude X Series:
Table of Contents

Advertisement

Available languages

Available languages

3.5
minimum clearance to combustible enclosures
1" [25mm] minimum all sides for vertical venting sections.
When passing through a ceiling, use firestop
W500-0028 (not supplied).
72" (182.8cm)
min. for typical application
84" (213cm) min.
for recess application
* Refer to "venting requirements" and "venting installation" sections.
** Clearances within the enclosure may be higher (refer to "minimum framing dimensions" section).
A
1" [25mm] minimum tous les côtés pour les sections
F
d'évacuation verticale.
En passant à travers un plafond, utilisez espaceur
coupe feu W500-0028 (non fourni).
Insulated
sleeve
Non-combustible
material
12"
[30.5cm]
F
AX36
54 7/8" (139.3cm)
34 13/16" (88.4cm)
Combustible
Non-combustible
Brick
3"
[76mm]
to top
3"
min.
2"
[51mm] to
sides / bottom
Firestop
assembly
(not supplied)
1" [25mm]
AX42
57 7/8" (147cm)
37 13/16" (96cm)
Combustible
Incombustible
Brique
3"
[76mm]
vers le
rough framing
0" [0mm] if non-combustible
finishing material is used
such as brick and stone.
A
+ rise
0" [0mm] si les matériaux
W415-1935 / E / 01.05.21
sont inombustible, comme
de la brique et de la pierre.
EN
23