3.4.5 Work area examples
If the charging station is put in a small area (A),
make sure that the distance to the boundary wire is
at a minimum 2 m / 6.6 ft. in front of the charging
station.
If the work area has a passage (B) with no guide
wire installed, the minimum distance between the
boundary wires is 2 m / 6.5 ft. With a guide wire
installed through the passage, the minimum
distance between the boundary wires is 60 cm / 24
in.
If the work area has areas which are connected by
a narrow passage (B), you can set the product to
first follow and then leave the guide wire to the
point it connects to the boundary wire (C). The
settings can be changed in
page 23 .
If the work area includes a secondary area (D),
To make a secondary area on page 16 .
refer to
Put the product in the secondary area and select
Secondary area mode .
D
B
C

3.5 Installation of the product

3.5.1 Installation tools
Hammer/plastic mallet: To simplify putting the
stakes into the ground.
Edge cutter/straight spade: To bury the boundary
wire.
Combination pliers: For cutting the boundary wire
and pressing the connectors together.
1411 - 007 - 23.09.2020
3.5.2 To install the charging station
Lawn Coverage on
A
When connecting the power supply, only use a power
outlet that is connected to an residual-current device
(RCD).
1.
Adjustable plier: For pressing the couplers
together.
WARNING:
Obey national regulations
about electrical safety.
WARNING:
The product is only to be
used with the power supply unit supplied by
McCulloch.
WARNING:
Do not put the power
supply at a height where there is a risk it can
be put in water. Do not put the power supply
on the ground.
WARNING:
Do not encapsulate the
power supply. Condensed water can harm
the power supply and increase the risk of
electrical shock.
WARNING:
Risk of Electric Shock.
Install only to an residual-current device
(RCD) when connecting the power supply to
the power outlet. Applicable to USA/Canada.
If power supply is installed outdoors: Risk of
Electric Shock. Install only to a covered
Class A GFCI receptacle (RCD) that has an
enclosure that is weatherproof with the
attachment plug cap inserted or removed.
CAUTION:
Do not make new holes in
the charging station plate.
CAUTION:
Do not put your feet on the
baseplate of the charging station.
WARNING:
The power supply cable
and extension cable must be outside the
work area to avoid damage to the cables.
Read and understand the instructions about where
to put the charging station. Refer to
where to put the charging station on page 12 .
To examine
Installation - 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rob s800967798103967798125

Table of Contents