Stealthwatch Management Console VE
will store flows for
l
you have
3 Data Nodes
l
7200 GB / 3 Data Nodes = 2400 GB (2.4 TB) per Data Node
l
Data Store Deployment Required Credentials
Prepare passwords for the following user accounts:
and
root
sysadmin
l
these during initial system configuration.
for each SMC, Data Node, and Flow Collector. You assign these using
admin
l
Appliance Setup Tool.
and
dbadmin
l
initializing the Data Store.
Data Store Networking and Switching Considerations
The following table provides an overview for the networking and switching
considerations when deploying Stealthwatch with a Data Store.
Network
Consideration
Necessary
Credentials
Inter-Data Node
Communications
© 2021 Cisco Systems, Inc. and/or its affiliates. All rights reserved.
, and
90 days
for each SMC, Data Node, and Flow Collector. You assign
for the Data Store. You assign these when
readonlyuser
Description
For each Data Node, Stealthwatch Management Console, and
Flow Collector:
Configured during initial System Configuration:
l
sysadmin
Configured using Appliance Setup Tool:
l
Configured during Data Store initialization:
readonlyuser
Establish a recommended round-trip time (RTT) latency of
l
under 200 microseconds between and among Data Nodes
Keep clock skew at 1 second or lower between and among
l
your Data Nodes.
Establish a recommended throughput of 6.4 Gbps or greater
l
Data Store Deployment Prerequisites and Recommendations
,
root
admin
,
dbadmin
- 15 -