Dometic RF60 Operating Manual page 22

Absorber refrigerator
Hide thumbs Also See for RF60:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Placing and connecting the device
Cable length
≤ 2.5 m
2.5 m – 4.0 m
4.0 m – 6.0 m
3. Connect the wires to a terminal block that is connected to the battery via a 15 A
fuse.
4. Install an isolating switch between both poles.
The minimum isolating distance between the two poles is 3 mm.
6.6
Connecting the device to a gas cylinder
!
WARNING!
This device may only be connected to the gas supply by a specialist in
accordance with the applicable regulations and standards.
A
NOTICE! Damage hazard
• Only use cylinders of propane or butane gas (not natural gas or city
gas) with an approved pressure reduction valve and suitable head.
• Observe the pressures which are permitted in your country. Use an
approved pressure regulator with a fixed setting:
– The following applies for Germany: DIN EN 16129.
– The following applies for Europe: EN 732, EN 521 and
EN 437:2003+A1:2009.
• The device may only be operated with hose lines in a perfect
technical condition. Replace any porous or damaged hose lines.
I
NOTE
If the gas flame extinguishes the ignition control shuts off the gas supply.
1. Check that pressure specification on the type plate is the same as the pressure
information on the pressure regulator on the propane or butane gas cylinder.
2. Connect the device to the gas hose as shown (fig. 6, page 6).
3. Connect the gas hose to the gas cylinder as shown (fig. 7, page 7).
22
Cable cross section
2.5 mm²
4.0 mm²
6.0 mm²
RF60, RF62
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rf62

Table of Contents