Removing The Back, Control Cover And Key Pad Assembly - LG LRGL5821S Service Manual

30" freestanding gas range
Table of Contents

Advertisement

REMOVING THE BACK, CONTROL COVER AND KEY PAD
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the gas
range handling the sheet metal part.
- Sharp edge may be present and you can cut yourself.
1. Turn off the electrical supply and gas supply going
to the range.
2. Pull the range away from the wall so that you can
access the rear panel.
3. Remove two wire covers by removing the screw.
4. Remove the 16 screws from the rear cover and
remove the cover.
5. Separate PCB assembly after unplugging the 6
connectors.
Main PCB
COMPONENT ACCESS
ASSEMBLY
Rear Cover
Motor Cover
6. Remove the 2 screws of the eyebrow from the
controller assembly and remove the eyebrow.
Eye brow
7. Remove the 7 screws on the controller assembly
and remove the assemblies in order.
2
8. Replace the control panel assembly.
3-2
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
1
Main PCB
2

Hide quick links:

Advertisement

Table of Contents
loading