Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
Control
Ambient temperature
Frost protection temperature
Temperature range
Sensor failure monitoring
Cable specification max.
Ball pressure test temperature
Pollution degree
Controller type
Software class
Storage temperature
4
Danfoss ECtemp Touch
42 kΩ
18 kΩ
6 kΩ
PWM (Pulse Width Modulation)
0° to +30°C
5°C to +9°C (default 5°C)
Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. floor: 20-35°C (if unrecov-
erable seal is broken then up to
45°C). Min. floor: 10-35°C, only
with combination of room and
floor sensor.
The thermostat has a built-in
monitoring circuit, which will
switch off the heating if the
sensor is disconnected or short-
circuited
1x4 mm
or 2x2,5 mm
2
75°C
2 (domestic use)
1C
A
-20°C to +65°C
2
Installation Guide