CHAPTER 3. REPAIR INSTRUCTION
Dowel for setting the position
NOTE (Assembling)
2.12 RLS PCB ASS'Y
(1) RLS PCB ASS'Y
1. Remove connection of the OPT FPC.
2. Remove the screw d.
3. Remove the claw and the two dowels, and remove the RLS PCB ASS'Y in the direction of the arrow.
NOTE (Assembling)
Align it with the claw and the two dowels.
(1)-2
d
Claw
(1)-1
OPT FPC
Fig. 3-14 RLS PCB ASS'Y
(1)-3
RLS PCB ASS'Y
NOTE (Assembling)
(1)-1
Dowel for setting the position
3-14
d
XA4-9140-257
2.5mm
METAL
M1.4
(SELF TAP)