Chapter 2 Communication Tool Software Configurator WD
2-1

Setting Items

The Configurator WD makes it possible to change the following setting
items.
Settings IP address
Automatic
getting of IP
2
address
Unit Name
IP Address
Subnet Mask The netmask of the HL-C21C
Default
Gateway
Protocol Mode
Command
Receive
Setting
Measurement
Value Output
Setting
Item
Acquires the IP address from the DHCP
server if [Get IP Address to auto] is selected.
Sets the IP address manually if [Use this IP
Address] is selected.
Used to set the unit name of the HL-C21C.
Used to set the IP address for the HL-C21C.
Set an IP address other than
0.*.*.*, 255.*.*.*, *.*.*.0 and *.*.*.255.
The gateway to the HL-C21C
Item
Action Mode
Communication
Mode
UDP-Server
Setting
(Source Port
No.)
Communication
Mode
Destination Unit
Number
Timeout
(*1)
Content
Content
Set the connecting operating
mode for the HL-C21C.
Select the standard mode or
iQSS mode.
Set the port number from the
range that the HL-C21C
opens.
Setting range: 1024-65535
(The setting will be fixed if
the iQSS mode is selected.)
Set the communication mode
for the HL-C21C.
Select [MEWTOCOL] or
[MCprotocol].
(The setting is fixed to
[MCprotocol] if the iQSS
mode is selected.)
Set the destination unit
number of the
communicating device.
Setting range: 1-99
Set the timeout period in
units of milliseconds.
Setting range: 1-10000
2-2
Default value
Use this IP
Address
HL-C2
192.168.1.5
255.255.255.0
192.168.1.1
Default value
Normal
HL-C2
Command
9094
MEWTOCOL
1
500