Gov. Basic Menu (Governor Basic Setting) - FUTABA CGY760R Manual

Hide thumbs Also See for CGY760R:
Table of Contents

Advertisement

G
B
OV.
This menu sets the governor's fundamental functions. The menu Servo limit point
setting must be set first.
" GOV. BASIC " screen from the " BASIC MENU " screen.
From 6/6
GOV. BASIC screen 1/6
(1) Governor: Governor active
Set the governor operation mode of CGY. The initial setting is "ACT
(active)" where, as the designation implies, the governor is active. If
you do not want to use governor, select "INH (Inhibit)".
Setting: ACT (Active) / INH (Inhibit)
(2) Gear Ratio:
Input the main rotor gear ratio by pushing the [ /+] or [ /-] key to select
the desired working mode.
Setting ranges: 1.00 ~ 50.00 t
M
ENU ( GOVERNOR BASIC SETTING )
ASIC
From the "SBUS2 rpm Slot"
of GOV. BASIC screen 6/6
Go to 2/6 from any cursor position
Notes:
• If the gear ratio is not properly set,
the set speed and actual engine
speed will be different.
• The gear ratio should be given in the
helicopter instruction manual. If the
helicopter instruction manual does
not give the gear ratio, calculate the
gear ratio as follows:
Note: When using the governor function, be sure
to make each setting of "GOV.BASIC".
Note: After completing the linkage of the throttle,
be sure to set the "Servo limit point setting" first,
and then set the other functions.
:
:
Initial setting: ACT
Initial value: 8.00 t
Engine
pinion gear
N2
Carry values less than 1/1000 to the
61
:
Rotor
main gear
N1
Gear ratio = N1/N2
next whole number.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cgy75545138860336674513886033636Gpb-1

Table of Contents