Troubleshooting
MiniMax Plus Troubleshooting/Check List
1. Look at the lights/which ones are on?
2. Check for correct voltage on both sides of the transformer.
3. Check Ignition wire connections on the module and the pilot ignitor.
4. Check position of pilot to the burner and check the components for correct spacing.
5. Check the wire harness and wire connections to the circuit board.
6. Check for true ground and good ground connections.
7. Push the Pool/Spa switch "ON" and turn Pots Cold to Hot.
8. Make sure the Pump is running and is primed.
9. Remove any Remote Control wires from the heater circuit board and replace the jumper wire
while testing.
J BOX
PACFAB 6800
DUAL
ELECTRONIC
THERMOSTAT
The wiring was crossed from
the Switch to the Board and
we used a Breaker (Reset)
that was external to the
Transformer.
Rev. C 12-1-00
TRANSFORMER
CHASSIS SHEET METAL
GRN
ON / OFF / ON
SWITCH
THERMISTOR PROBE
BLUE
IID
GAS VALVE
WHT
WHT
WHT
WHT
PRESSURE
SWITCH
IGNITION
MODULE
GRN
2 3
IID PILOT
HI TENSION
WIRE
HILIMITS
P/N 38033