Auxiliary Supply - TDK-Lambda SWS-L Series Manual

Compact and high-power ac/dc power supply
Hide thumbs Also See for SWS-L Series:
Table of Contents

Advertisement

SWS
600L, 1000L
Output - CNT· AUX · ALM : 100VAC 1min. (100mA)
AC(L)
AC(N)
COM
CNT1
CNT2
TOG
Output Voltage External Control (PV)
Output voltage external control function is available. Output
voltage can be varied by applying an external voltage (1–6V) to
"PV" terminal and "COM" terminal. Please consider the follow-
ing characteristics.
Connection method
Power Supply
+S
+Vm
-S
-Vm
PV
COM
Output Voltage Linearity
120%
110%
Nominal
Output
Voltage
20%
0
1V
PV voltage (Nominal Input Voltage)
Output Voltage Derating
120%
110%
Nominal
Output
Voltage
20%
0
Load Current
Note 1. Regarding output voltage adjustment below 20%, please
consult our sales.
・All specifications are subject to change without notice.
+S
+Vm
+
-
-Vm
-S
Withstand
PC
Voltage
Tester
PV
ALM
AUX
G1
G2
Load
External voltage
5V
6V
5.5V
83% 100%
90%
Note 2. For 3.3V output model, limit output voltage variation range
at 30% - 120%. At PV voltage variation 1.5V - 6V.
For 15V output model, limit output voltage variation range
at 20% - 130%. At PV voltage variation 1V - 6.5V.
For 48V output model, limit output voltage variation range
at 20% - 116.7%. At PV voltage variation 1V - 5.8V.
For 60V output model, limit output voltage variation range
at 20% - 110%. At PV voltage variation 1V - 5.5V.
Output Peak Current
For 24V, 48V output model, please meet the following condi-
tions. Reduce peak current value according to output derating
as section 4-2.
Input voltage range : AC170V - 265V
Continuous Peak output time (τ) : Within 10 seconds
Peak output current (Ip) : Within the rated peak output current
Average DC output current (Im) : Within the rated output cur-
rent, Iav
Ip
aA
0A
τ
T
Ip : Peak output current (A)
Iav : Rated output current (A)
Im : Average output current (A)
τ : Peak current pulse width (sec)
T
: Period (sec)

Auxiliary Supply

Auxiliary supply (12V, 0.1A max) is provided to ease customer
application. Aux voltage is functionally isolated from all other
signal terminals and output terminals, and it is always available
as long as input power in the specifi ed voltage range is present.
Im
( Ip - a ) × τ
Im
=
+a
T
τ
Duty
× 100 (%)
=
T
Duty
:
up to 35 (%)
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents