8.2.2 Reading the water pressure of the heating
system
Menu → Installer level → System configuration [System --
--] → Water pressure
– This function allows you to read the water pressure of
the heating system.
8.2.3 Reading the hot water generation status
Menu → Installer level → System configuration [System --
--] → Domestic hot water
– You can use this function to read the hot water genera-
tion status (Charged, Not charged).
8.2.4 Reading the software version
Menu → Installer level → System configuration [System --
--] → Control modules
– You can use this function to read the software version
of the display, the heat generator and the radio receiver
unit.
8.2.5 Setting the control type
Menu → Installer level → System configuration [System --
--] → Control type
0020131978_00 VRT 350f Installation instructions
Operating and display functions 8
– Select this function to set the type of room temperature
control:
– Two-point corresponds to an On/Off control system
– Analogue corresponds to a modulating control system
8.2.6 Setting the distance adjustment
Menu → Installer level → System configuration [System --
--] → Distance adjustment
– This function allows you to optimally adjust the switching
behaviour of the controller to the room size or the radi-
ator layout:
– Positive values: slower controller switching behaviour
– Negative values: faster controller switching behaviour
The Distance adjustment function is only available if you
have set Analogue under the Control strategy function
8.3

System configuration: Heat generator

8.3.1
Reading the status of the heater
Menu → Installer level → System configuration [Heater 1 -
---] → Status
– This function allows you to read the current status of the
heater (boiler). Off, Heating (heating mode), hot water
generation.