Fujitsu D2619-N Technical Manual

Fujitsu D2619-N Technical Manual

For primergy rx/tx300 s6

Advertisement

Quick Links

Technical Manual - English
System Board D2619-N
for PRIMERGY RX/TX300 S6
Technical Manual
Edition March 2010

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2619-N

  • Page 1 Technical Manual - English System Board D2619-N for PRIMERGY RX/TX300 S6 Technical Manual Edition March 2010...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
  • Page 3 It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. Technical Manual D2619-N (RX/TX300 S6)
  • Page 4 (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery Technical Manual D2619-N (RX/TX300 S6)
  • Page 6 Technical Manual D2619-N (RX/TX300 S6)
  • Page 7: Table Of Contents

    Switches ......37 Replacing the lithium battery ....39 Technical Manual D2619-N (RX/TX300 S6)
  • Page 8 Contents Technical Manual D2619-N (RX/TX300 S6)
  • Page 9: Introduction

    DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D2619-N BIOS Setup Utility for PRIMERGY RX300 S6 and TX300 S6" manual.
  • Page 10 Notational conventions Introduction Technical Manual D2619-N (RX/TX300 S6)
  • Page 11: Important Information

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2619-N (RX/TX300 S6)
  • Page 12 (this information doesn’t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". Technical Manual D2619-N (RX/TX300 S6)
  • Page 13 Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2619-N (RX/TX300 S6)
  • Page 14: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2619-N (RX/TX300 S6)
  • Page 15: Environmental Protection

    Environmental protection Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    – up to 3 dual rank or 2 quad rank RDIMM memory rows per channel – up to 2 UDIMM memory rows per channel – ECC multiple-bit error detection and single-bit error correction – memory scrubbing functionality – Single Device Data Correction (SDDC) function (Chipkill™) – Mirroring – Sparing Technical Manual D2619-N (RX/TX300 S6)
  • Page 18 – 1x connector for USB Flash Module (optional) – 1x connector for Trusted Platform Module (optional) – 1x power connector (12 V and 5 V auxiliary) – 1x combined connector for HDD power supply and fan Technical Manual D2619-N (RX/TX300 S6)
  • Page 19 – CSS functionality – power consumption control – text console redirection – Advanced Video Redirection - AVR – remote storage Security features – Supervisor and User password – recovery BIOS support – flash write protection against virus Technical Manual D2619-N (RX/TX300 S6)
  • Page 20 – 415 x 417mm – ACPI 2.0, OnNow, PCI Express 2.0, LPC 1.1, WfM 2.0, SHDG 3.0, MPS 1.4, IPMI 2.0, PCI SHPC 1.0 and PCI Express card electromechanical specification rev. 1.0, USB2.0, SATA 2.0 Technical Manual D2619-N (RX/TX300 S6)
  • Page 21 TPM or the system board is faulty you will not be able to access your data. – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2619-N (RX/TX300 S6)
  • Page 22: Main Memory

    The memory modules are organized in 6 channels (A - F). Each channel has three slots (1-3). The channels A - C are controlled by CPU 1 and the channels D - F are controlled by CPU 2. Technical Manual D2619-N (RX/TX300 S6)
  • Page 23: Types Of Memory Modules

    Technology: DDR3 800 / 1066 / 1333 unbuffered single rank (SR) or dual rank (DR) LV-UDIMM memory modules with ECC. ® LV-UDIMM memory modules are not supported by Intel Xeon™ processors of the 5500 series. Technical Manual D2619-N (RX/TX300 S6)
  • Page 24 – If one quad rank DIMM is used, it must be populated in DIMM slot 0 (farthest away from the CPU) of a given channel. For system relevant information please refer to the configurator of the server: http://ts.fujitsu.com/products/standard_server/tower/primergy_tx300s6.html http://ts.fujitsu.com/products/standard_server/rack/primergy_rx300s6.html (for the EMEA market) (for the Japanese http://primeserver.fujitsu.com/primergy/system.html market) Technical Manual D2619-N (RX/TX300 S6)
  • Page 25: Modes Of Operation

    Depending on the mode of operation there are different population requirements for the main memory. For system relevant information please refer to the configurator of the server: http://ts.fujitsu.com/products/standard_server/tower/primergy_tx300s6.html http://ts.fujitsu.com/products/standard_server/rack/primergy_rx300s6.html (for the EMEA market) (for the Japanese http://primeserver.fujitsu.com/primergy/system.html market) Technical Manual D2619-N (RX/TX300 S6)
  • Page 26: Pci Slots

    Description PCIe x4 slot for RAID controller PCIe x4 slot PCIe x4 slot (if slot 2 empty: x8) PCIe x4 slot PCIe x4 slot (if slot 4 empty: x8) PCIe x8 slot PCIe x8 slot Technical Manual D2619-N (RX/TX300 S6)
  • Page 27: Screen Resolution

    (integrated Remote Management Controller). The following functions are supported: Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature sensor, measurement of the ambient temperature by a C temperature sensor. Technical Manual D2619-N (RX/TX300 S6)
  • Page 28 BIOS Setup, iRMC S2’s Web interface or via the ServerView Operations Manager. PRIMERGY Local Diagnostic LEDs Optical signaling through the LEDs on the system board identifies defective modules and components (CSS functionality) as well as gaining information on the PDA (Prefailure Detection and Analysis). Technical Manual D2619-N (RX/TX300 S6)
  • Page 29: Connectors And Indicators

    CPU 2 DIMM 2E CPU 2 DIMM 1E Battery CPU 2 DIMM 3F Slot 1 PCIe CPU 2 DIMM 2F Intrusion HD LED CPU 2 DIMM 1F DIP Switch Figure 4: Internal connectors of the system board D2619-N Technical Manual D2619-N (RX/TX300 S6)
  • Page 30 Power Connector 1 Power supply connector 1 Power Connector 2 Power supply connector 2 HDD Power/FAN Power supply connector for fans and HDDs Control Intrusion Intrusion connector (only used for TX300 S6) HD LED Connector for HDD activity LED Technical Manual D2619-N (RX/TX300 S6)
  • Page 31 LEDs are only visible, if the cover of the server has been opened. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the CSS indicate button. Technical Manual D2619-N (RX/TX300 S6)
  • Page 32 I - PS CTRL ok green on Power supply controller okay K - PS CTRL orange on Power supply controller error error L - main power green on main power okay Technical Manual D2619-N (RX/TX300 S6)
  • Page 33: Connector Panel

    Service LAN connector, for iRMC S2 server management function System LAN connector (LAN 2) System LAN connector (LAN 1) The serial connector COM1 can be used as default interface or to communicate with the iRMC S2. Technical Manual D2619-N (RX/TX300 S6)
  • Page 34 Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Steady green signal when a LAN connection exists. link/transfer Remains dark when no LAN connection exists. (system LAN) Flashes green when LAN transfer takes place. Technical Manual D2619-N (RX/TX300 S6)
  • Page 35 Steady yellow signal in the event of a LAN transfer rate (system LAN) of 1 Gbit/s Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Technical Manual D2619-N (RX/TX300 S6)
  • Page 36: Settings

    Figure 8: Position of the jumper TPM Enable Default setting: pins 1 and 2 are connected. Without this setting the TPM function is disabled. Default Signal Description TPM_RESET_L Reset of the TPM ICH_TMP_DIS_L Reset of the ICH10 Technical Manual D2619-N (RX/TX300 S6)
  • Page 37: Switches

    Switch 2 is used to define whether the password is skipped at system startup, if the password protection is enabled in the BIOS Setup (in Security menu, the Password on boot field must be set to Enabled). Technical Manual D2619-N (RX/TX300 S6)
  • Page 38 Settings Features Technical Manual D2619-N (RX/TX300 S6)
  • Page 39: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2619-N (RX/TX300 S6)
  • Page 40 Replacing the lithium battery Technical Manual D2619-N (RX/TX300 S6)

Table of Contents