Fujitsu D2529 Technical Manual
Fujitsu D2529 Technical Manual

Fujitsu D2529 Technical Manual

For tx300 s4

Advertisement

Quick Links

System Board D2529
for TX300 S4
Technical Manual
Edition November 2007

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2529

  • Page 1 System Board D2529 for TX300 S4 Technical Manual Edition November 2007...
  • Page 2 Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2007 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Replacing the lithium battery ....35 Abbreviations ....... 37 Technical Manual D2529 (TX300 S4)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2529, which can be ® equipped with one or two Intel processors. You will find further information in the BIOS description. Further information about drivers is provided in the readme files on the hard disk, on the supplied “ServerStart“...
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2529 (TX300 S4)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2529 (TX300 S4)
  • Page 9 Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2529 (TX300 S4)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2529 (TX300 S4)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2529 (TX300 S4)
  • Page 12 You will find further information on this at www.fujitsu-siemens.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
  • Page 13: Features

    – Super I/O controller (SMSC 47M107) – Flash EPROM for: – local BIOS; flashable via bootable USB device, LAN or optional floppy disk – SMSC8700 Fast Ethernet RMII Phy – iRMC S2 with integrated VGA graphic controller Technical Manual D2529 (TX300 S4)
  • Page 14 – 1 dual RJ45 LAN connector PCI slots – 1 PCI-X 1.0b (64 Bit / 133 MHz) – 2 PCI-Express 1.0a (2 Gbyte/s bandwidth) – 4 PCI-Express 1.0a, alternatively configurable as 4x2 Gbyte/s or 2x4 Gbyte/s bandwidth Technical Manual D2529 (TX300 S4)
  • Page 15 The system board is optional equipped with a TPM (Trusted Platform Module) by the manufacturer. This module enables programs from third party manufac- turers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). Technical Manual D2529 (TX300 S4)
  • Page 16 Overview Features The TPM is activated via the BIOS system (for more information, refer to the Fujitsu Siemens Computers BIOS manual). CAUTION! – When using the TPM, note the program descriptions provided by the third party manufacturers. – You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions.
  • Page 17: Main Memory

    Options Guide of your server. Slots for riser cards DIMM C/D (branch 1) DIMM A/B (branch 0) Figure 2: Slots for the riser cards If only one riser card is occupied slot DIMM A/B will be populated. Technical Manual D2529 (TX300 S4)
  • Page 18 – Each pair consists of identical memory modules. There are three modes of operation for the main memory: – Non-mirrored mode – Mirrored mode – Sparing mode Depending on the mode of operation there are different population requiren- ments. Technical Manual D2529 (TX300 S4)
  • Page 19 1A + 1B, 1C + 1D (minimum configuration) 2A + 2B, 2C + 2D (upgrade 1); 3A + 3B, 3C + 3D (upgrade 2); 4A + 4B, 4C + 4D (upgrade 3) Technical Manual D2529 (TX300 S4)
  • Page 20: Pci(E) Slots

    Slot 6 PCI Express Slot 5 PCI Express Slot 4 PCI X Slot 3 PCI Express Slot 2 PCI Express Slot 1 PCI Express Figure 4: Mechanical PCI slots (the PCI slot numbers on the rear) Technical Manual D2529 (TX300 S4)
  • Page 21 An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing). PCI Express devices send their interrupts through messages. The interrupts are defined by the system design. Technical Manual D2529 (TX300 S4)
  • Page 22 Int B, C, D, A Steckplatz 1 PCIe x4 Int A, B, C, D Assignment of the PCI interrupts If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required. Technical Manual D2529 (TX300 S4)
  • Page 23: Screen Resolution

    I C temper- ature sensor. Fan speed monitoring The CPU, power supply unit and system fans are monitored. Fans that are no longer available, blocked or sticky fans are detected. Technical Manual D2529 (TX300 S4)
  • Page 24 LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via ServerView. PRIMERGY Diagnostic LEDs LEDs on the system board enable to identify defective modules and compo- nents as well as gaining information on the PDA. Technical Manual D2529 (TX300 S4)
  • Page 25: Leds

    Features LEDs LEDs Figure 5: LEDs on the system board Technical Manual D2529 (TX300 S4)
  • Page 26 - overheating of one of the sensors - sensor defect - fan defect - CPU error - voltage incorrect - Software detected an error C - Identification blue server is identified via ServerView Technical Manual D2529 (TX300 S4)
  • Page 27 K - Aux Power yellow auxiliary power ok auxiliary power not available L - Memoryr memory module ok orange error in memorymodule M - LAN-Trans- yellow siehe page 31 ferrate N -LAN- green/ siehe page 31 Link/Aktivität Technical Manual D2529 (TX300 S4)
  • Page 28: Interfaces And Connectors

    Interfaces and connectors Features Interfaces and connectors Figure 7: Schematic view of the system board D2529 Technical Manual D2529 (TX300 S4)
  • Page 29 8 = Front panel 19 = USB intern 9 = USB front 20 = DIP-Schalter (siehe page 10 = Floppy disk drive 21 = HD LED 11 = SATA1 22 = LPC bus (for assembly only) Technical Manual D2529 (TX300 S4)
  • Page 30: External Ports

    Interfaces and connectors Features 3.7.1 External ports 10 9 Figure 8: External ports of the system board D2529 1 = Printer port (optional) 7 = USB port 4 2 = PS/2 mouse connector 8 = VGA port 3 = LAN connector (service LAN)
  • Page 31 LAN 1 LAN transfer green + transfer rate 10 Mbit/s rate yellow green transfer rate 100 Mbit/s yellow transfer rate 1000 Mbit/s LAN 2 LAN green LAN connection link/activity no LAN connection flashing LAN transfer Technical Manual D2529 (TX300 S4)
  • Page 32: Settings With Dip Switches

    The system boots from the Flash BIOS medium (floppy disk, DVD/CD- ROM, USB sstick) and reprograms the system BIOS on the board. The System BIOS is started with the system BIOS from the system board (default setting). Technical Manual D2529 (TX300 S4)
  • Page 33 To write and delete floppy disks, the write-protection in BIOS Setup must be disabled (in menu Security, the field Diskette Write must be set to Enabled). The floppy disk drive is write-protected. Floppy disks can be read, written and deleted (default setting). Technical Manual D2529 (TX300 S4)
  • Page 34 Settings with DIP switches Features Technical Manual D2529 (TX300 S4)
  • Page 35: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2529 (TX300 S4)
  • Page 37: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit Double Data Rate DIMM Dual In-line Memory Module Technical Manual D2529 (TX300 S4)
  • Page 38 Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD Fully Buffered DIMM Hot-plug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced IOOP Intelligent Organization Of PCI Technical Manual D2529 (TX300 S4)
  • Page 39 Small Computer System Interface Local Area Network Light Emitting Diode Low Pin Count Multi Processor Specification MegaTransfers per Second Non Maskable Interrupt Original Equipment Manufacturer OHCI Open Host Controller Interface Operating System Peripheral Components Interconnect Technical Manual D2529 (TX300 S4)
  • Page 40 Puls Wide Modulation Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks Remote Service Board ReSeT Real Time Clock Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction Technical Manual D2529 (TX300 S4)
  • Page 41 System Management Bus Server Management Mode Symmetrically Multi Processing Trusted Platform Module UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2529 (TX300 S4)
  • Page 43 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents