1. Safety Instructions
To ensure sufficient convection cooling, always maintain a safety distance of ≥ 50mm from all ventilated
surfaces while the device is in operation.
The device is not recommended to be placed on low thermal conductive surface, for example,
plastics.
Note that the enclosure of the device can become very hot depending on the ambient temperature
and load of the power supply. Do not touch the device while it is in operation or immediately after
power is turned OFF. Risk of burning!
Do not touch the terminals while power is being supplied. Risk of electric shock.
Prevent any foreign metal, particles or conductors to enter the device through the openings during
installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure
Warning: When connecting the device, secure Earth connection before connecting L and N. When
disconnecting the device, remove L and N connections before removing the Earth connection.
2. Device Descriptions
Refer to Fig. 1.:
 Input terminal block connector
 Output terminal block connector
 DC Voltage adjustment potentiometer
 DC OK control LED (Green)
 DC Fan
3. Installation of the Device
The unit is protected with internal fuse (not replaceable) at L pin and it has been tested
and approved on 20A (UL) and 16A (IEC) branch circuits without additional protection device.
Refer to Fig. 2.:
Ⓐ Mounting holes for power supply assembly onto the mounting surface. The power supply shall
be mounted on minimum 4 mounting holes using M4 screw.
Ⓑ Input / Output connector
Ⓒ This surface belongs to customer's system or panel where the power supply is mounted.
• Use Flexible cable (strand or solid) of AWG No. 14-12. The torque at the Input connector shall
not exceed 11.98Kgf.cm. The torque at the Output connector shall not exceed 16.59Kgf.cm.
The insulation stripping length should not exceed 0.275" or 7mm (Refer to Fig. 3).
4. Installation of Mounting Accessories
Refer to Fig. 4.:
Only use M4 screw ≤ 6mm through the base mounting holes. This is to keep a safe
distance between the screw and internal components.
Recommended mounting torque for tightening: 4〜8Kgf.cm.
5. Input Voltage Derating Curve
Output derating is required at 85-115Vac (Refer to Fig. 5).
6. Maximum 5000 Meters Operating Altitude
REV 01
5
Base surface
Fig. 1. Device Descriptions
Side Mounting
Base Mounting
(Horizontal)
C
B
C
A
A
Fig. 2 Mounting Orientations
Lug
Mounting
Chassis of
accessories
the device
Mounting
screw
Xmm max.
6mm max.
Fig. 4. Mounting Screw
PMC-48V600W1B☐
Side surface
Top surface
1
2
3
4
Base Mounting
(Vertical)
C
B
B
A
7mm max.
Stripped Wire
Fig. 3. Wire Type
Load (%)
100
80
85
115
Fig. 5. Input Voltage Derating Curve
Base Mounting
(Vertical)
C
A
B
(Vac)
www.DeltaPSU.com

Advertisement

loading

Summary of Contents for Delta PMC-48V600W1B Series

  • Page 1 Instruction Manual PMC-48V600W1B☐ 1. Safety Instructions Side surface • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 50mm from all ventilated surfaces while the device is in operation. Top surface • The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
  • Page 2 PMC-48V600W1B☐ 使用说明书 取扱説明書 1. 安全规范 1. 安全上の注意 • 電源装置を十分に冷却するため、運転中はすべての通気面の周囲に 50mm 以上のスペースを • 与通风表面保持至少 50mm 的安全距离,以确保对流冷却充分。 保って下さい。 • 本产品不适合摆放在低热导体,例如: 塑胶。 • 本装置を低熱伝導面(例: プラスチック)に設置することは避けて下さい。 • 受环境温度及产品负载的影响,本机外壳温度会很高,因此在上电时或切断电源后短时间 • 電源装置の周囲を囲うと、周囲温度や電源の負荷によって非常に熱くなることがありますので 内不要触摸本机,以免烫伤。 注意して下さい。電源装置の運転中やパワーをオフにした直後は、装置に触れないで下さい。 • 请勿在上电时触摸连接端子,以防电击危险。 やけどの恐れがあります。 • 安装过程中,应避免金属元件或金属导体通过空隙或通风孔进入到产品内,否则会引起下 • 電源運転中はターミナルに触らないで下さい。感電の危険があります。 列状况。 • 装置を箱から出してから設置するまでの間、金属の異物や導電体が装置の中に入らないように -电击;安全危害;火灾;产品异常 して下さい。こうした異物は、感電、火事、装置の故障を引き起こす危険があります。 •...