Wolf Dual Fuel Range Installation Manual page 6

Table of Contents

Advertisement

Available languages

Available languages

Specifications
Gas Supply
Installation must comply with local codes, or in the
absence of local codes, with the National Fuel Gas Code.
Locate the gas supply within the shaded area shown in the
illustration on the following page.
The range is equipped for use with natural or liquid pro-
pane (LP) gas. The product rating plate has information
on the type of gas that should be used. For rating plate
location, refer to the illustration below. If this information
does not agree with the type of gas available, check with
the local gas supplier. The gas pressure regulator is built
into the unit.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
RATING PLATE
Rating plate location
6 | Wolf Customer Care 800.222.7820
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
The range must be connected to a regulated gas supply.
The supply line must be equipped with an approved exter-
nal gas shut-off valve located near the range in an acces-
sible location. Do not block access to the shut-off valve.
Refer to the illustration below.
A gas supply of 3/4"
ID line must be provided to the
(19)
range. If local codes permit, a certified, 3'
or 3/4"
ID flexible metal appliance connector is recom-
(19)
mended to connect the units 1/2" NPT female inlet to the
gas supply line. Pipe joint compounds suitable for use with
natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of .5 psi
. The appliance must be isolated from the gas
(3.5 kPa)
supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test
pressures equal to or less than .5 psi
Wolf natural gas ranges will function up to 10,250'
in altitude without adjustment and LP gas ranges will func-
tion up to 8,600'
. If the installation exceeds these
(2621 m)
elevations, contact an authorized Wolf dealer for a high
altitude conversion kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve
long, 1/2"
(.9 m)
(13)
.
(3.5 kPa)
(3124 m)