Cleaning; Cleaning The Convection Air Openings; Combustion Air - Intake; Cleaning The Pellet Container - RIKA SUMO MULTIAIR Operating Manual

Table of Contents

Advertisement

9. CLEANING

Depending on pellet consumption, a message prompting cleaning of
the stove appears on the display in regular intervals� This message
can be acknowledged on the Touch Display, while continuing
operation� Perform a cleaning cycle at the next opportunity�
Subsequently, reset the counter in the SETTINGS menu / RESETS
submenu, as per operating instructions of TOUCH DISPLAY�
Tip
The message will only stop reappearing once you have reset the
feed volume in the SETTINGS / Resets menu�
Note
Your stove must be switched off and cooled before any maintenance
work is performed� Only work on the unit when the mains plug has
been disconnected�

Cleaning the convection air openings

Vacuum clean any dust deposits from the convection air openings
at regular intervals�
The stove should be cleaned thoroughly prior to the start of the
heating season to prevent excess odour�
Note
To prevent your stove from overheating of the internal components,
do never cover the convection fins!

Combustion air - intake

If necessary, please also clean the air intake with a hoover�
Note
Only when the stove is cold! You could vacuum out embers – FIRE
RISK!

Cleaning the pellet container

Do not refill the completely empty container immediately; remove
the residues (dust, chippings etc�) from the empty container� The unit
must be disconnected from the mains!

Cleaning the flue pipes

(annually)
Remove the flue pipes� Inspect and clean the chimney connection�
Brush off any soot and dust deposits in the fire and in the flue pipes
and vacuum�
Note
Accumulated fly ash in the flue gas channels may impair the
performance of the stove and pose a safety risk�

Bearings

(annually)
All built-in bearings (pellet screw, turning grid) should be checked�
Clean or replace bearings depending on condition�

Checking door seal

(annually)
The condition of the seals at doors and glass should be checked at
least once a year� Repair or replace seals depending on condition�
Note
Only intact seals ensure your stove works perfectly!
Cleaning the flue gas channels and flue
gas collecting duct
The flues are situated under and behind the combustion chamber�
Note
Only work on the unit when the mains plug has been disconnected
and the stove has cooled completely�
Note
During assembly / dismantling do not allow objects (screws etc�) to
fall into the pellet container – they can block the screw conveyor
and damage the stove�
Note
During any conversion work, take particular care of your fingers
and any panels and stove attachments� Select soft bases to
prevent scratches to your living space furniture and stove panels�
Open the pellet container lid�
Open the decorative glass door� Remove the convection fins by
lifting them straight up�
Loosen the wing nut on the lid of the cleaning opening, tilting the
eyescrew forwards� Open the lid� When cleaning the stove, be sure
to either keep the cleaning lid open or to laterally pull it out from its
hinges to remove it�
Note
Please mind your fingers! They could be injured by the lid falling
down�