Normally, "All On" for less than one second during power-up. All segments dimly lit when
power is "Off" is normal when an external signal is applied to the encoder inputs (motor or
master) or serial port from an externally powered device. The signals applied to the inputs
cannot exceed 5.5V level required to drive logic common or drive damage will occur.
Diagnostic Analog Output Test Points
The drive has two 8-bit real-time Analog Outputs which may be used for diagnostics,
monitoring or control purposes. These outputs are referred to as Channel 1 and Channel 2.
They can be accessed from the Command Connector on the drive or from the Diagnostics
Analog Output Pins located on the front of the drive.
Each Channel provides a programmable Analog Output Source.
Analog Output Source options are:
•
Velocity Command
•
Velocity Feedback
•
Torque Command (equates to Torque Command Actual parameter)
•
Torque Feedback
•
Following Error
Default Analog Output Source:
•
Channel 1 = Velocity Feedback
•
Channel 2 = Torque Command
Output
1
2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Source
Offset
Velocity Feedback