Diagnostic Analog Output Test Points - Emerson Epsilon Eb Series Reference Manual

En drives
Table of Contents

Advertisement

Normally, "All On" for less than one second during power-up. All segments dimly lit when
power is "Off" is normal when an external signal is applied to the encoder inputs (motor or
master) or serial port from an externally powered device. The signals applied to the inputs
cannot exceed 5.5V level required to drive logic common or drive damage will occur.

Diagnostic Analog Output Test Points

The drive has two 8-bit real-time Analog Outputs which may be used for diagnostics,
monitoring or control purposes. These outputs are referred to as Channel 1 and Channel 2.
They can be accessed from the Command Connector on the drive or from the Diagnostics
Analog Output Pins located on the front of the drive.
Each Channel provides a programmable Analog Output Source.
Analog Output Source options are:
Velocity Command
Velocity Feedback
Torque Command (equates to Torque Command Actual parameter)
Torque Feedback
Following Error
Default Analog Output Source:
Channel 1 = Velocity Feedback
Channel 2 = Torque Command
Output
1
2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Source
Offset
Velocity Feedback
Torque Command
Diagnostics and Troubleshooting
Scale
0
600 RPM/volt
30 percent/volt for selected
0
motor
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents