6.2.2
Viewing customer service program
Customer Service Program
Displayed
Step
step
0
0
Check Coil
1
0
Drain Pump
2
1,2
Filling
3
3,4
Pause
4
5,6,10,11 Drain Pump
5
12,13,14 Filling + Main Pump
6
15
Main Pump + Soap
Dispenser
7
16
Main Pump + Aqua
Sensor Calibration
8
17
Main Pump + Heating
9
18
Pause
10
19
Main Pump
11
20
Main Pump + Rinse
Agent + Heating
12
21
Main Pump + Heating
13
22
Main Pump
14
24
Drain Pump
Hint: If a failure occurs the program goes on, stops or ends according to the failure handling.
Remark: Filling can not be stepped over
702_58300000130262_ara_en_b
Can advance
Action
step
no
partly
yes
yes
no
yes
partly
yes
yes
yes
yes
yes
no
Water
Time
Temperature
amount
--
15s
72s
3.0 L
10s
20s
empty Sump base completely empty
96s
4.0 L
10s
110s
104°F
5s
5s
60s
149° F
15s
--
Remarks
Checks pumps and other components
(when switched on)
Drain pump O K
Checks if water level above filter level
Checks water level
Checks if water level at top of coarse filter -
main pump starts at displayed step 13
Start main pump
# of dispenser coil impulses = rinse agent
setting
About 2.5°F/min
Displays "0" when done