FORM 160.81-O1 (1020)
ISSUE DATE 10/05/2020
The Control Center provides the required formatting
control codes for the printers above when the printer
is selected on the PRINTER screen in the instructions
below. These codes are transmitted through the serial
interface to the printer to provide a proper print format.
Different printers require different formatting control
codes. Other printers might provide proper operation
when connected to the Control Center. However, the
print format may not be correct or as desired. Proceed
with caution and use the following guidelines if an un-
listed printer is selected:
1. All must be capable of RS-232 Serial communica-
tions.
2. Primary differences between printers involve the
formatting control codes required by the printer.
These codes are sent from the Control Center to
the printer. For example, Weigh -Tronix printers
require a control code to select 40 column width.
This same code is interpreted by the Okidata
printer as an instruction to print wide characters.
In some instances, a printer will ignore a code it
cannot interpret.
3. The Control Center requires a busy signal from
the printer when the printer receive buffer is full.
This causes the Control Center to momentarily
terminate data transmission until the printer can
accept more data. The busy signal polarity must
be asserted low when busy.

PRINTER CONNECTIONS

Connect the printers to the Control Center Microboard
as follows. Only one printer can be connected at a
time.

Okidata 182, 182 turbo, 184 turbo

MICROBOARD
PRINTER
J2-4
Pin 3
J2-2
Pin 11
J2-9
Pin 7
Cabinet

Weigh-Tronix

MICROBOARD
PRINTER
J2-4
Pin 2
J2-2
Pin 5
J2-9
Pin 7
Cabinet
JOHNSON CONTROLS
FUNCTION
Tx (data to printer)
DSR
(busy signal from printer)
Gnd
Shield
FUNCTION
Tx (data to printer)
DSR
(busy signal from printer)
Gnd
Shield

Seiko

MICROBOARD
PRINTER
J2-4
Pin 3
J2-2
Pin 8
J2-9
Pin 5
Cabinet

Hardware

The hardwire required to connect the printer is as follows:
• Cable – #18 AWG stranded 50ft. maximum
length.
• Connectors –
- Microboard: None. Strip 1/4" insulation from
wire and insert into screw terminal block.
- Printers: Okidata - 25 pin plug DB-25P or
equivalent; Shell DB-C2-J9 or equivalent.
Weigh-Tronix - Same as Okidata. Cable as-
sembly available from Weigh-Tronix. Seiko -
9-Pin D-type Subminiature (DB-9 pin male).

PRINTER SETUP

The selected printer must be configured as follows. Re-
fer to manual provided by Printer manufacturer with
respective Printer.

Okidata 182, 182 Turbo, 184 Turbo Printer

CONTROL BOARD SWITCH SETTINGS
SW1
ON
SW2
OFF
SW3
OFF
SW4
OFF
SW5
ON
SW6
OFF
SW7
ON
SW8
OFF
If equipped with a SUPER SPEED serial board:
CONTROL BOARD SWITCH SETTINGS
SW1-1
ON
SW1-2
ON
SW1-3
ON
SW1-4
ON
SW1-5
ON
SW1-6
ON
SW1-7
OFF
SECTION 4 - PRINTERS
FUNCTION
Tx (data to printer)
DSR
(busy signal from printer)
Gnd
Shield
Unslashed 0
Unslashed 0
Unslashed 0
Form Length 11 In.
Form Length 11 In.
Auto Line Feed OFF
8 Bit Data
Enable Front Panel
Odd Or Even Parity
No Parity
8 Bit Data
Protocol Ready/Busy
Test Select
Print Mode
SDD (-) Pin 11