York AHV8 UH Series User's Information, Maintenance And Service Manual
York AHV8 UH Series User's Information, Maintenance And Service Manual

York AHV8 UH Series User's Information, Maintenance And Service Manual

High efficiency tubular heat exchanger series

Advertisement

Quick Links

USER'S INFORMATION,

MAINTENANCE AND
SERVICE MANUAL
HIGH EFFICIENCY
TUBULAR HEAT EXCHANGER SERIES
MODEL: AHV8*UH
Two Stage Variable Speed Upflow / Horizontal / Low NOx)
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
USER'S INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . 3
Operating Instructions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
To Turn Off the Appliance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Removing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Blower Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Motor Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . . 4
SAFETY SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTACT INFORMATION
• Go to website at www.york.com click on "contact", then click on "contact form" and follow the instructions.
• Contact us by mail:
The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.
FIRE OR EXPLOSION HAZARD - Failure to follow safety
warnings exactly could result in serious injury, death, or prop-
erty damage.
-
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
-
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
(including cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire depart-
ment.
-
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.

TABLE OF CONTENTS

FURNACE MAINTENANCE SECTION . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Burner Removal/Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Cleaning the Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
HEATING AIRFLOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
ADJUSTMENT OF FAN CONTROL SETTINGS . . . . . . . . . . . . . . . .6
Heating Indoor Fan Off Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Continuous Blower Operation: . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Delay Tap Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Humidistat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Hot Surface Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .8
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
York International
Consumer Relations
5005 York Drive
Norman, OK 73069
SECTION I: USER'S INFORMATION

SAFETY

1.
The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.
2.
Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.
3.
The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.
4.
Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.
5.
Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
6.
Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
271002-UUM-A-0407

Advertisement

Table of Contents
loading

Summary of Contents for York AHV8 UH Series

  • Page 1: Table Of Contents

    LIMITED WARRANTY ........16 CONTACT INFORMATION • Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions. • Contact us by mail:...
  • Page 2: Instructions For Examining The Furnace Installation

    271002-UUM-A-0407 INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION VENT PRESSURE INDUCER It is the owner’s responsibility to ensure that an annual inspection of the SWITCH MOTOR entire heating portion of the unit is made by a qualified service agency. Examine the furnace as outlined below in steps “1 - 6” before each ROLLOUT heating season.
  • Page 3: How Your Gas Furnace Works

    271002-UUM-A-0407 HOW YOUR GAS FURNACE WORKS To Turn Off the Appliance: Set the thermostat to lowest setting. Your furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. Turn off all electric power to the appliance if service is to be per- For this reason, you may never have given much thought to the way formed.
  • Page 4: Furnace User Maintenance

    271002-UUM-A-0407 FURNACE USER MAINTENANCE TABLE 1: Filter Sizes Cabinet Side (in) Side (cm) Bottom (in) Bottom (cm) Size 16 x 25 4.06 x 6.35 14 x 25 3.56 x 6.35 Before proceeding, be sure the area is well ventilated. Turn 16 x 25 4.06 x 6.35 16 x 25...
  • Page 5: Furnace Maintenance Section

    271002-UUM-A-0407 FURNACE MAINTENANCE SECTION NOTE: It is recommended that replacement gaskets be available before removing vent motor. The furnace should be cleaned and adjusted by a certified dealer or Remove six mounting screws that hold the vent motor to the qualified service contractor once a year or before the start of every restrictor plate.
  • Page 6: Control Board

    271002-UUM-A-0407 CONTROL BOARD 2nd Stage is satisfied, 1st Stage still calling. • If a Single Stage Thermostat is used, the Furnace will stay on Variable speed motors will adjust the motor speed in order to maintain High Fire until the thermostat is satisfied. the indoor fan CFM.
  • Page 7: Continuous Blower Operation

    271002-UUM-A-0407 CONTINUOUS HEAT HI HEAT BLOWER FAN SPEED DEHUMIDISTAT DELAY DELAY OFF DELAY JUMPER JUMPER JUMPER JUMPER JUMPER VOLTAGE TERMINALS COOLING PROFILE JUMPER BLOWER SPEED JUMPERS FIGURE 7: Furnace Control Board Continuous Blower Operation: Humidistat When a humidistat is installed in the system, the “Humidistat Installed?” The blower will run continuously whenever the wall thermostat fan jumper on the control board should be moved to the “YES”...
  • Page 8: Furnace Control Diagnostics

    271002-UUM-A-0407 FURNACE CONTROL DIAGNOSTICS 9 RED FLASHES: Indicates reversed line voltage polarity or grounding problem. Both heating and cooling operations will be affected. Check The furnace has built-in, self-diagnostic capability. If a system problem polarity at furnace and branch. Check furnace grounding. Check that occurs, a blinking LED shows a fault code.
  • Page 9 271002-UUM-A-0407 W2 SIGNAL HIGH INDUCER HIGH STAGE PRESSURE SWITCH AND 2ND STAGE MAIN VALVE CIRCULATOR HIGH HIGH HEAT SPEED HEAT DELAY 30 SEC. CALL HIGH HEAT AFTER LOW HEAT IS ESTABLISHED 2ND STAGE CLOSED HIGH LIMIT OPEN W1 SIGNAL INDUCER CLOSED LOW STAGE PRESSURE...
  • Page 10: Replacement Parts List

    271002-UUM-A-0407 SECTION III: REPLACEMENT PARTS LIST 38,43 Unitary Products Group...
  • Page 11 271002-UUM-A-0407 ITEM DESCRIPTION ITEM DESCRIPTION FABRICATED PARTS (Continued) MOTOR PAN, BASE MOTOR/MODULE COMPLETE (Programmed PANEL, BLOWER ACCESS (Magnet) ECM PROGRAMMED MODULE (Less Motor) PANEL, TOP MOTOR, BLOWER (MOTOR ONLY, LESS ECM MODULE) WRAPPER, INSULATED MOTOR, VENTOR ASS’Y CHANNEL, TOE PLATE ELECTRICAL CHOKE, PSC CONTROL, HIGH LIMIT...
  • Page 12 Click on the “Brand Links” button b. Click on the “Customer Service” button • You can contact us by mail. Just send a written request to: York International Consumer Relations 5005 York Drive Norman, OK 73069 Unitary Products Group...
  • Page 13: Wiring Diagram

    271002-UUM-A-0407 SECTION IV: WIRING DIAGRAM FIGURE 9: Wiring Diagram Unitary Products Group...
  • Page 14 271002-UUM-A-0407 NOTES Unitary Products Group...
  • Page 15 271002-UUM-A-0407 NOTES Unitary Products Group...
  • Page 16: Limited Warranty

    For Owner's Information: PRODUCT MODEL. NO. ____________________ INSTALLATION DATE ______________________________ UNIT SERIAL NO. _________________________ INSTALLING DEALER ______________________________ Subject to change without notice. Printed in U.S.A. 271002-UUM-A-0407 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 167188-UUM-B-0806 Unitary 5005 Norman...

Table of Contents