Typical Installation
A
P
The Typical Installation drawing shown above is only a
guide for selecting required and optional accessories
for an automatic airless spray system. Contact your
Graco representative for assistance in designing a
system to meet your particular needs.
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the Typical Installa-
tion, Figures, and Parts Drawing.
Ventilate the Spray Booth
WARNING
To prevent hazardous concentrations of toxic
and/or flammable vapors, spray only in a properly
ventilated spray booth. Never operate the spray
gun unless ventilation fans are running.
Mount the Gun
Mount the gun on a 0.50 in. (12.7 mm) diameter rod
(Y) on a mounting fixture or a spray machine. See Fig.
1 and the Typical Installation. The tip of the gun
should be 12 in. (305 mm) from the surface of the
workpiece (N).
6
306830
Installation
F
G
B
C
H
E
K
N
R
J
D
07589
Connect the Air Lines
Clean all lines and connections of dirt, burrs, etc. and
blow them out with clean air before connecting them to
the system. The air supply line (K) should contain an
air filter (A) to remove harmful dirt and moisture from
the compressed air.
Use a normally closed 3-way air solenoid valve (F) to
control the spray gun (J). Attach a grounded air supply
line (K) from the 3-way valve to the 1/4 npsm(m) air
inlet adapter (6) of the Gun. See Fig. 1.
K
6
21
Spray
Tip
Fig. 1
L
M
KEY
A
Air Line Filter
B
Pump
C
Back Pressure Valve
D
Fluid Supply Line
E
Air Regulator (if required)
F
3-Way Air Valve
G
Fluid Return Line
H
Surge Tank with Drain Valve
J
Automatic Spray Gun
K
Air Line
L
Timer
M
Timer Switch
N
Workpiece
P
Bleed-Type Master Air Valve
R
Fluid Regulator
Y
X